Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ALUMA-WELD, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of ALUMA-WELD, INC. in 199 EXTRUSION PLACE, HOT SPRINGS, AR 71901 (NAICS 336612). OSHA activity number 343763629.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Aluma-Weld, INC. — free Get an email when a new federal OSHA severe-injury report for Aluma-Weld, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
ALUMA-WELD, INC.
Site address
199 EXTRUSION PLACE
City
HOT SPRINGS
State
AR
ZIP
71901
Mailing
199 EXTRUSION PLACE, HOT SPRINGS, AR 71901
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336612
Employees
156
Ownership type
A

6 citations on file for this inspection.

1910.106 E02 IV A

Serious Gravity 5 1 instance 3 exposed
Issued
May 15, 2019
Abate by
Jun 13, 2019
Penalty
Initial $9,377 · Current $5,626 Reduced

Hazardous substances 0040

29 CFR 1910.106(e)(2)(iv)(a): Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be kept in covered containers when not actually in use.  On or about February 4, 2019 and at times prior thereto, the employer failed to ensure that the portable containers, used to carry acetone, had a cover when not being used.
Recent events (2)
  • — I (S) $5626.2
  • — Z (S) $9377

1910.106 E06 I

Serious Gravity 10 1 instance 3 exposed
Issued
May 15, 2019
Abate by
Jun 13, 2019
Penalty
Initial $13,127 · Current $7,876 Reduced

Hazardous substances 0040P125R208

29 CFR 1910.106(e)(6)(i): Adequate precautions were not taken to prevent the ignition of flammable vapors from sources such as open flames; lightning; smoking; cutting and welding; hot surfaces; frictional heat; static, electrical, and mechanical sparks; spontaneous ignition, including heat-producing chemical reactions; and radiant heat:  On or about February 4, 2019 and at times prior thereto, in the foam department, employer failed to ensure that acetone was not used near radiant heat produced by "Dayton Infrared Radiant Heater, Model No. 3E134D."
Recent events (2)
  • — I (S) $7876.2
  • — Z (S) $13127

1910.106 E06 II

Serious Gravity 5 1 instance 3 exposed
Issued
May 15, 2019
Abate by
Jun 13, 2019
Penalty
Initial $9,377 · Current $5,626 Reduced

Hazardous substances 0040

29 CFR 1910.106(e)(6)(ii): Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), were dispensed into containers without the nozzle and container being electrically interconnected.  On or about February 4, 2019 and at times prior thereto, the employer failed to ensure that the acetone dispensing drums in the storage area were bonded.
Recent events (2)
  • — I (S) $5626.2
  • — Z (S) $9377

1910.1200 H01

Serious Gravity 5 1 instance 3 exposed
Issued
May 15, 2019
Abate by
Jun 13, 2019
Penalty
Initial $7,501 · Current $4,501 Reduced

Hazardous substances 0040

29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals or materials in their work area at the time of their initial assignment and whenever a new hazard was introduced into their work area:  On February 4, 2019 and at times prior thereto, the employer failed to ensure that each employee in the foam department was given effective training on the hazardous chemicals in the work area.
Recent events (2)
  • — I (S) $4500.6
  • — Z (S) $7501

1910.138 B

Other-than-serious 1 instance 3 exposed
Issued
May 15, 2019
Abate by
Jun 13, 2019
Penalty
Initial $1,052 · Current $631 Reduced

Hazardous substances 0040

29 CFR 1910.138(b): Employers did not base the selection of the appropriate hand protection on an evaluation of the performance characteristics of the hand protection relative to the task(s) performed, conditions present, duration of use, and the hazards and the potential hazards identified:  On or about February 4, 2019 and at times prior thereto, the employer did not ensure that employees wore hand protection rated for use with acetone.
Recent events (2)
  • — I (O) $631.2
  • — Z (O) $1052

1910.157 C01

Other-than-serious 1 instance 3 exposed
Issued
May 15, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): Employer did not provide portable fire extinguishers which were mounted, located, and identified, so as to be readily accessible for employee use  a) On or about February 6, 2019 and at times prior thereto, the employer failed to ensure unobstructed access to the portable fire extinguisher located on the south side of the production building near the stairwell.  b) On or about February 6, 2019 and at times prior thereto, the employer failed to ensure unobstructed access to a portable fire extinguisher located at the station adjacent to the "foaming" station.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Aluma-Weld, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343763629.