Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SPINWELD, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SPINWELD, INC. in W227 N546 WESTMOUND ROAD, WAUKESHA, WI 53186 (NAICS 332912). OSHA activity number 343924973.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Spinweld, INC. — free Get an email when a new federal OSHA severe-injury report for Spinweld, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
SPINWELD, INC.
Site address
W227 N546 WESTMOUND ROAD
City
WAUKESHA
State
WI
ZIP
53186
Mailing
W227 N546 WESTMOUND ROAD, WAUKESHA, WI 53186
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332912
Employees
20
Ownership type
A

5 citations on file for this inspection.

1910.178 L01 I

Serious Gravity 5 1 instance 5 exposed
Issued
Sep 10, 2019
Abate by
Oct 4, 2019
Penalty
Initial $4,168 · Current $1,500 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):    (a) The employer did not ensure that each powered industrial truck operator was competent to operate a powered industrial truck as required.
Recent events (3)
  • — F (S) $1500
  • — C (S) $4168
  • — Z (S) $4168

1910.242 B

Serious Gravity 5 2 instances 2 exposed
Issued
Sep 10, 2019
Abate by
Oct 4, 2019
Penalty
Initial $4,168 · Current $1,500 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:    (a) On or about April 11, 2019, an employee used compressed air nozzle which was not reduced and was approximately 95 p.s.i. at the Haas VF-3B CNC machine (serial no. 1050856) to clean debris off product and the machine.    (b) On or about April 11, 2019, an employee used compressed air nozzle which was not reduced and was approximately 62 p.s.i. at the Haas SL-10 CNC machine (serial no. 3081817) to clean debris off product and the machine.
Recent events (3)
  • — F (S) $1500
  • — C (S) $4168
  • — Z (S) $4168

1910.303 G01

Serious Gravity 1 1 instance 6 exposed
Issued
Sep 10, 2019
Abate by
Oct 4, 2019
Penalty
Initial $2,501 · Current $1,500 Reduced
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:    (a) On or about April 11, 2019, in the friction welding machine area, metal baskets and a cart were temporarily being stored directly in front of electric equipment, which did not allow access to the electrical disconnect if an emergency occurred within the equipment and electrical power had to be immediately removed.
Recent events (3)
  • — F (S) $1500
  • — C (S) $2501
  • — Z (S) $2501

1910.304 G05

Serious Gravity 1 1 instance 1 exposed
Issued
Sep 10, 2019
Abate by
Oct 4, 2019
Penalty
Initial $2,501 · Current $0 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:     (a) On or about April 11, 2019, the portable fan used for air circulation, by the parts oven, had a plug with a missing grounding pin, thereby exposing employees to electrical shock hazards.
Recent events (3)
  • — F (S) $0
  • — C (S) $2501
  • — Z (S) $2501

1910.212 A01

Repeat Gravity 10 9 instances 8 exposed
Issued
Sep 10, 2019
Abate by
Oct 26, 2020
Penalty
Initial $11,669 · Current $5,240 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    (a) On or about April 11, 2019, the Haas VF-3B CNC Vertical Machining Center (serial no. 1050856) had by-passed interlocks which allowed employees to open the doors while the machine was in operation and exposed employees to rotating parts and flying chips.    (b) On or about April 11, 2019, the Haas SL-30 CNC Lathe (serial no. 1050856) had by-passed interlocks which allowed employees to open the doors while the machine was in operation and exposed employees to rotating parts and flying chips.    (c) On or about April 11, 2019, the Haas ST-30 CNC Lathe (serial no. 3091257) had by-passed interlocks which allowed employees to open the doors while the machine was in operation and exposed employees to rotating parts and flying chips.    (d) On or about April 11, 2019, the Caterpillar Inertia Welder WC124 (model no. 250-B, serial no. 44S105) was not provided with adequate guarding to protect employees from injury from rotating parts during operation of the unit.    (e) On or about April 11, 2019, the Caterpillar Inertia Welder WC125 (model no. 250-B, serial no. 44S111) was not provided with adequate guarding to protect employees from injury from rotating parts during operation of the unit.    (f) On or about April 11, 2019, the Caterpillar Inertia Welder WC123 (model no. 250, serial no. 27J91) was not provided with adequate guarding to protect employees from injury from rotating parts during operation of the unit.    (g) On or about April 11, 2019, the Caterpillar Inertia Welder WC145 (model no. 250, serial no. unknown) was not provided with adequate guarding to protect employees from injury from rotating parts during operation of the unit.    (h) On or about April 11, 2019, the Caterpillar Inertia Welder WC116 (model no. 100, serial no. unknown) was not provided with adequate guarding to protect employees from injury from rotating parts during operation of the unit.    (i) On or about April 11, 2019, the Caterpillar Inertia Welder WC121 (model no. 180B , serial no. 59U80) was not provided with adequate guarding to protect employees from injury from rotating parts during operation of the unit.    Spinweld, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.212(a)(1), which was contained in OSHA inspection number 1194549, citation number 1, item number 4 and was affirmed as a final order on3/27/17, with respect to a workplace located at W227N546 Westmound Drive, Waukesha, WI 53186.
Recent events (4)
  • — P (R) $5240
  • — F (R) $5240
  • — C (R) $11669

View Spinweld, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343924973.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.