BUFFALO, NY —
OSHA Inspection: EJS CONTRACTORS INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of EJS CONTRACTORS INC. in 1166 JEFFERSON AVENUE, BUFFALO, NY 14208 (NAICS 238130). OSHA activity number 343946000.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EJS CONTRACTORS INC.
- Site address
- 1166 JEFFERSON AVENUE
- City
- BUFFALO
- State
- NY
- ZIP
- 14208
- Mailing
- 104 LOWDEN STREET, DELRAN, NJ 08075
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 12
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.404 F06
- Issued
- May 30, 2019
- Penalty
- Initial $1,932 · Current $0 Reduced
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) On or about 4/16/19, in the Electric Room on apartment building construction site at 1166 Jefferson Avenue, Buffalo, NY: A Makita Model MAC5200 air compressor supplied air to operate the powered nailers that employees were using to install Tyvek Commercial Wrap on the east side of the building exterior from the basket of an aerial lift. The plug on the cord of the compressor lacked a ground prong. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — J (O) $0
- — C (S) $1932
- — Z (S) $1932
1926.453 B02 V
- Issued
- May 30, 2019
- Penalty
- Initial $3,789 · Current $1,500 Reduced
General-duty citation text
29 CFR 1926.453(b)(2)(v): A safety harness with lanyard attached to the boom or basket was not worn by employee(s) working from an aerial lift: a) On or about 4/16/19, on apartment building construction site at 1166 Jefferson Avenue, Buffalo, NY: Two employees were installing Tyvek Commercial Wrap on the east side of the building exterior from inside of the elevated basket of a JLG Model 660SJ aerial lift. Both employees were wearing full body harnesses, but neither was tethered to the boom or basket of the lift. The employees were exposed to potential fall of approx. 30 ft. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — J (S) $1500
- — C (S) $3789
- — Z (S) $3789
1926.501 B01
- Issued
- May 30, 2019
- Penalty
- Initial $3,031 · Current $1,500 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a) On or about 4/16/19, on apartment building construction site at 1166 Jefferson Avenue, Buffalo, NY: Originally, doorway wall openings to balconies on the 2nd and 3rd floors were guarded by a wooden guardrail system consisting of a top rail and a midrail to keep unauthorized employees from accessing the balconies. To gain entrance to the balconies to install the windows, employees removed the guardrails, then used a personal fall arrest system while on the balconies installing the windows. However, when the window installation was completed, only the top rails were put back in place. This created a hazard where other unauthorized employees on the site could walk onto the unguarded balconies. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — J (S) $1500
- — C (S) $3031
- — Z (S) $3031
1926.1053 B04
- Issued
- May 30, 2019
- Penalty
- Initial $2,273 · Current $1,500 Reduced
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a) On or about 4/16/19, on apartment building construction site at 1166 Jefferson Avenue, Buffalo, NY: An employee was standing on the sixth rung of an unopened Werner 8 ft. fiberglass stepladder that was setting on the ground and propped against the wall at the southeast corner of the building, while he was installing Tyvek Commercial Wrap on the wall. The stepladder was not designed to be used in this manner. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — J (S) $1500
- — C (S) $2273
- — Z (S) $2273
More inspections at EJS Contractors INC.
View EJS Contractors INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343946000.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.