DOWNERS GROVE, IL —
OSHA Inspection: RMS PROPERTIES, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of RMS PROPERTIES, INC. in 1206-1530 75TH ST., DOWNERS GROVE, IL 60515 (NAICS 238120). OSHA activity number 343954657.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RMS PROPERTIES, INC.
- Site address
- 1206-1530 75TH ST.
- City
- DOWNERS GROVE
- State
- IL
- ZIP
- 60515
- Mailing
- 1111 N. PLAZA DRIVE SUITE 200, SCHAUMBURG, IL 60173
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238120
- Employees
- 10
- Ownership type
- A
Citations
10 citations on file for this inspection.
1926.451 B01
- Issued
- Jul 3, 2019
- Abate by
- Aug 25, 2019
- Penalty
- Initial $10,210 · Current $3,425 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) On or about April 24, 2019, working section of a metal framed scaffold were not fully planked between uprights, exposing employees to a fall hazard of approximately 21 feet. Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $3425
- — Z (S) $10210
1926.451 F07
- Issued
- Jul 3, 2019
- Abate by
- Aug 25, 2019
- Penalty
- Initial $10,210 · Current $3,425 Reduced
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person. On or about April 24, 2019, a scaffold was erected by persons who were not competent in scaffold erection, exposing employees to the hazards associated with a fall and scaffold collapse. Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
- — I (S) $3425
- — Z (S) $10210
1926.451 G01
- Issued
- Jul 3, 2019
- Abate by
- Aug 25, 2019
- Penalty
- Initial $10,210 · Current $3,425 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: On or about April 24, 2019, employees performing work from a metal frame scaffold were not protected from a fall, exposing employees to a fall of approximately 21 feet. Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $3425
- — Z (S) $10210
1926.453 A02
- Issued
- Jul 3, 2019
- Abate by
- Aug 25, 2019
- Penalty
- Initial $10,210 · Current $3,425 Reduced
General-duty citation text
29 CFR 1926.453(a)(2): Aerial lifts were "field modified" for uses other than those intended by the manufacturer, the modification had not been certified in writing by the manufacturer or by any other equivalent entity. Modification did not conform with all applicable provisions of ANSI A92.2-1969. On or about April 24, 2019, an employee modified a JLG 660SJ aerial lift by attaching 1.5"x 7/8"x 1/4" steel chain to the basket and using it as a hoist to raise a steel stud roof section, exposing the employee to the hazards associated with an aerial lift collapse. Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
- — I (S) $3425
- — Z (S) $10210
1926.502 D23
- Issued
- Jul 3, 2019
- Abate by
- Aug 25, 2019
- Penalty
- Initial $7,294 · Current $2,445 Reduced
General-duty citation text
29 CFR 1926.502(d)(23): Personal fall arrest systems were attached to guardrail systems or to hoists: On or about April 24, 2019, an employee's fall arrest system was anchored to the guardrail of an aerial lift, exposing the employee to a fall of over 17 feet. Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
- — I (S) $2445
- — Z (S) $7294
1926.502 E08 I
- Issued
- Jul 3, 2019
- Abate by
- Aug 25, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(e)(8)(i): Unless the snaphook is a locking type and designed for the following connections, snaphooks shall not be engaged directly to webbing, rope or wire rope. On or about April 24, 2019, employees fall arrest snaphook were directly attached to the webbing of their lanyards, exposing employees to the unintentional opening of their snap hook. Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B01
- Issued
- Jul 3, 2019
- Abate by
- Aug 25, 2019
- Penalty
- Initial $20,421 · Current $6,855 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. On or about April 24, 2019, employees were not protected from a fall while walking/ working from the roof of a commercial building, exposing employees to a fall of approximately 17 feet. RMS Properties, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(1), which was contained in OSHA inspection number 1358166, citation number 1, item number 1 and was affirmed as a final order on January 23, 2019, with respect to a workplace located at 1400 Algonquin rd. Algonquin, IL 60102. Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (R) $6855
- — Z (R) $20421
1926.251 B01
- Issued
- Jul 3, 2019
- Abate by
- Aug 25, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.251(b)(1): Welded alloy steel chain sling(s) did not have permanently affixed durable identification stating size, grade, rated capacity, and sling manufacturer: On or about April 24, 2019, an employee used a welded steel chain as a sling to hoist a fabricated steel roof section. The sling did not have a permanently affixed identification tag, exposing employees to the hazards associated with hoisting and rigging. Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.453 B02 IV
- Issued
- Jul 3, 2019
- Abate by
- Aug 25, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.453(b)(2)(iv): Employee(s) working in an aerial lift were not standing firmly on the floor of the basket: On or about April 24, 2019, an employee was not standing on the floor of the aerial lift basket, exposing the employee to a fall of over 25 feet. Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.453 B02 VI
- Issued
- Jul 3, 2019
- Abate by
- Aug 25, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.453(b)(2)(vi): Boom and basket load limits specified by the manufacturer were exceeded: On or about April 24, 2019, three employees were working from an aerial lift designed and rated for two workers exceeded the maximum employee limit for the aerial lift, exposing employees to the hazards associated with three workers working from an aerial lift designed for two. Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at RMS Properties, INC.
View RMS Properties, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238120)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343954657.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.