Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SUPERIOR DAIRY, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SUPERIOR DAIRY, INC. in 4719 NAVARRE ROAD, CANTON, OH 44706 (NAICS 311520). OSHA activity number 344078100.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Superior Dairy, INC. — free Get an email when a new federal OSHA severe-injury report for Superior Dairy, INC. is published. One employer, no account, unsubscribe in one click.
Site address
4719 NAVARRE ROAD
City
CANTON
State
OH
ZIP
44706
Mailing
4719 NAVARRE ROAD, CANTON, OH 44706
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311520
Employees
250
Ownership type
A

4 citations on file for this inspection.

1910.147 D04 I

Serious Gravity 10 1 instance 2 exposed
Issued
Apr 20, 2020
Penalty
Initial $12,000 · Current $12,000
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices shall be affixed to each energy isolating device by authorized employees.  On or about May 17, 2019 the employer failed to ensure that the energy isolating devices of the Four-Head (350R2) blow mold rotogranulator were operatied in a manner to isolate the hazardous energies of the equipment prior to performing maintenance. Hazardous energies include mechanical and electrical.   Superior Dairy was previously cited for a violation of this occupational safety and health standard 29 CFR 1910.147(d)(3), which was contained in OSHA inspection number 1296891, citation number 1, item number 1 and was affirmed as a final order on May 19, 2018 with respect to a workplace located at 4719 Navarre Road, Canton, OH 44706.  Superior Dairy was previously cited for a violation of this occupational safety and health standard 29 CFR 1910.147(d)(3), which was contained in OSHA inspection number 1296897, citation number 1, item number 1b and was affirmed as a final order on May 19, 2018 with respect to a workplace located at 4719 Navarre Road, Canton, OH 44706
Recent events (3)
  • — C (S) $12000
  • — F (S) $12000
  • — Z (S) $12000

1910.147 D04 II

Serious Gravity 10 1 instance 2 exposed
Issued
Apr 20, 2020
Penalty
Initial $12,000 · Current $12,000
29 CFR 1910.147(d)(4)(ii): Lockout devices, where used, shall be affixed in a manner to that will hold the energy isolating devices in a "safe" or "off" position.   On or about May 17, 2019 the employer failed to ensure that the energy isolating devices of the Four-Head (350R2) blow mold rotogranulator were operatied in a manner to isolate the hazardous energies of the equipment prior to performing maintenance. Hazardous energies include mechanical and electrical.   Superior Dairy was previously cited for a violation of this occupational safety and health standard 29 CFR 1910.147(d)(3), which was contained in OSHA inspection number 1296891, citation number 1, item number 1 and was affirmed as a final order on May 19, 2018 with respect to a workplace located at 4719 Navarre Road, Canton, OH 44706.  Superior Dairy was previously cited for a violation of this occupational safety and health standard 29 CFR 1910.147(d)(3), which was contained in OSHA inspection number 1296897, citation number 1, item number 1b and was affirmed as a final order on May 19, 2018 with respect to a workplace located at 4719 Navarre Road, Canton, OH 44706
Recent events (3)
  • — C (S) $12000
  • — F (S) $12000
  • — Z (S) $12000

1910.147 D04 III

Serious Gravity 10 1 instance 2 exposed
Issued
Apr 20, 2020
Penalty
Initial $12,000 · Current $12,000
29 CFR 1910.147(d)(4)(iii): Tagout devices, where used, shall be affixed in such a manner as will clearly indicate that the operation or movement of energy isolating devices from the "safe" or "off" position is prohibited.  On or about May 17, 2019 the employer failed to ensure that the energy isolating devices of the Four-Head (350R2) blow mold rotogranulator were operatied in a manner to isolate the hazardous energies of the equipment prior to performing maintenance. Hazardous energies include mechanical and electrical.   Superior Dairy was previously cited for a violation of this occupational safety and health standard 29 CFR 1910.147(d)(3), which was contained in OSHA inspection number 1296891, citation number 1, item number 1 and was affirmed as a final order on May 19, 2018 with respect to a workplace located at 4719 Navarre Road, Canton, OH 44706.  Superior Dairy was previously cited for a violation of this occupational safety and health standard 29 CFR 1910.147(d)(3), which was contained in OSHA inspection number 1296897, citation number 1, item number 1b and was affirmed as a final order on May 19, 2018 with respect to a workplace located at 4719 Navarre Road, Canton, OH 44706
Recent events (3)
  • — C (S) $12000
  • — F (S) $12000
  • — Z (S) $12000

1910.147 D03

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 12, 2019
Penalty
Initial $65,637 · Current $12,000 Reduced
29 CFR 1910.147(d)(3): All energy isolating devices that are needed to control the energy to the machine or equipment was not physically located and operated in such a manner as to isolate the machine or equipment from the energy sources:    On or about May 17, 2019 the employer failed to ensure that the energy isolating devices of the Four-Head (350R2) blow mold rotogranulator were operatied in a manner to isolate the hazardous energies of the equipment prior to performing maintenance. Hazardous energies include mechanical and electrical.     Superior Dairy was previously cited for a violation of this occupational safety and health standard 29 CFR 1910.147(d)(3), which was contained in OSHA inspection number 1296891, citation number 1, item number 1 and was affirmed as a final order on May 19, 2018 with respect to a workplace located at 4719 Navarre Road, Canton, OH 44706.    Superior Dairy was previously cited for a violation of this occupational safety and health standard 29 CFR 1910.147(d)(3), which was contained in OSHA inspection number 1296897, citation number 1, item number 1b and was affirmed as a final order on May 19, 2018 with respect to a workplace located at 4719 Navarre Road, Canton, OH 44706
Recent events (3)
  • — F (S) $12000
  • — C (R) $65637
  • — Z (R) $65637

View Superior Dairy, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344078100.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.