HILLIARD, OH —
OSHA Inspection: PASATO CONSTRUCTION LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PASATO CONSTRUCTION LLC in LOT 240 3561 SWITCHGRASS COURT, HILLIARD, OH 43026 (NAICS 238130). OSHA activity number 344111992.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PASATO CONSTRUCTION LLC
- Site address
- LOT 240 3561 SWITCHGRASS COURT
- City
- HILLIARD
- State
- OH
- ZIP
- 43026
- Mailing
- 176 N. SOUTHAMPTON AVENUE, COLUMBUS, OH 43204
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 4
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.21 B02
- Issued
- Jul 29, 2019
- Abate by
- Aug 16, 2019
- Penalty
- Initial $4,376 · Current $1,750 Reduced
General-duty citation text
29 CFR 1926.21(b)(2): The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury. a. On or before June 25, 2019, the employer failed to train employees on the hazards of the worksite or the regulations required to control of eliminate the hazards, thereby exposing employees to struck-by, electrical contact, fall, or other hazards.
Recent events (2)
- — I (S) $1750.2
- — Z (S) $4376
1926.102 A01
- Issued
- Jul 29, 2019
- Abate by
- Aug 8, 2019
- Penalty
- Initial $3,126 · Current $1,250 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation. a. On or before June 25, 2019, where employees used pneumatic nail guns to secure roof sheathing, the employees' eyes were not protected, thereby being exposed to struck-by hazards. b. On or before June 25, 2019, where employees used electrically operated circular saws to cut roof sheathing, the employees' eyes were not protected, thereby being exposed to struck-by hazards.
Recent events (2)
- — I (S) $1250.4
- — Z (S) $3126
1926.404 F06
- Issued
- Jul 29, 2019
- Abate by
- Aug 8, 2019
- Penalty
- Initial $1,875 · Current $750 Reduced
General-duty citation text
29 CFR 1926.404(f)(6): Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous. a. On or before June 25, 2019, where employees used an extension cord to provide electrical power for a circular saw, the ground prong was missing from the male end of the cord, thereby exposing employees to a 125 volt electrical contact hazard.
Recent events (2)
- — I (S) $750
- — Z (S) $1875
1926.405 G02 IV
- Issued
- Jul 29, 2019
- Abate by
- Aug 8, 2019
- Penalty
- Initial $1,875 · Current $750 Reduced
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Strain relief. Flexible cords shall be connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws. a. On or before June 25, 2019, where employees used an air compressor to provide air for pneumatic nail guns, the strain relief clamp was not used exposing the interior conductors, thereby exposing employees to a 125 volt electrical contact hazard.
Recent events (2)
- — I (S) $750
- — Z (S) $1875
1926.20 B01
- Issued
- Jul 29, 2019
- Abate by
- Aug 16, 2019
- Penalty
- Initial $8,752 · Current $3,501 Reduced
General-duty citation text
29 CFR 1926.20(b)(1): It shall be the responsibility of the employer to initiate and maintain such programs as may be necessary to comply with this part. a. On or before June 25, 2019, the employed failed to initiate and maintain a safety and health program such as but not limited to a personnel protective equipment program, thereby exposing employees to struck-by hazards. b. On or before June 25, 2019, the employed failed to initiate and maintain a safety and health program such as but not limited to an electrical safety program, thereby exposing employees to a 125 volt electrical contact hazard. c. On or before June 25, 2019, the employed failed to initiate and maintain a safety and health program such as but not limited to a fall protection program, thereby exposing employees to an 11 foot fall hazard. Pasato Construction LLC was previously cited for a repeat violation of this occupational safety and health standard, which was contained in OSHA inspection number 1385149, citation number 1, item number 1 and was affirmed as a final order on April 9, 2019 with respect to a workplace located at 176 N. Southampton Avenue Columbus, OH 43204
Recent events (2)
- — I (R) $3500.8
- — Z (R) $8752
1926.501 B13
- Issued
- Jul 29, 2019
- Abate by
- Aug 8, 2019
- Penalty
- Initial $21,879 · Current $8,752 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems. a. On or before June 25, 2019, where employees were sheathing the porch roof of a new construction house, the employees were not protected from falls, thereby being exposed to an 11 foot fall hazard. b. On or before June 25, 2019, where employees were sheathing the garage roof of a new construction house, the employees were not protected from falls, thereby being exposed to an 11 foot fall hazard. Pasato Construction LLC was previously cited for a repeat violation of this occupational safety and health standard, which was contained in OSHA inspection number 1385149, citation number 2, item number 1 and was affirmed as a final order on April 9, 2019 with respect to a workplace located at 176 N. Southampton Avenue Columbus, OH 43204 Pasato Construction LLC was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 1261777, citation number 1, item number 1 and was affirmed as a final order on October 18, 2017 with respect to a workplace located at 1810 Gingerfield Way, Sunbury, OH 43074.
Recent events (2)
- — I (R) $8751.6
- — Z (R) $21879
More inspections at Pasato Construction LLC
View Pasato Construction LLC's full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344111992.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.