Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: LATEXCO, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of LATEXCO, LLC in 975 GERRARD RD., LAVONIA, GA 30553 (NAICS 326299). OSHA activity number 344454996.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Latexco, LLC — free Get an email when a new federal OSHA severe-injury report for Latexco, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
LATEXCO, LLC
Site address
975 GERRARD RD.
City
LAVONIA
State
GA
ZIP
30553
Mailing
975 GERRARD RD., LAVONIA, GA 30553
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326299
Employees
65
Ownership type
A

5 citations on file for this inspection.

1910.28 B01 I

Other-than-serious 1 instance 4 exposed
Issued
Dec 3, 2019
Abate by
Feb 28, 2020
Penalty
Initial $5,470 · Current $3,280 Reduced
29 CFR 1910.28(b)(1)(i): Each employee on a walking/working surface having an unprotected side or edge which was four feet (1.2m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.                                                                                      On 11/19/19, at the Lavonia facility at the vessels in the facility, employees are exposed to fall hazards as they remove guardrails on the mezzanine level to enter vessels and there is no fall protection around the tops of the vessels exposing employees to fall hazards greater than 18 ft..
Recent events (2)
  • — I (O) $3280
  • — Z (S) $5470

1910.147 C06 I B

Other-than-serious 1 instance 10 exposed
Issued
Dec 3, 2019
Abate by
Jan 22, 2020
Penalty
Initial $5,470 · Current $3,280 Reduced
29 CFR 1910.147(c)(6)(i)(B): The periodic inspection of the energy control procedure was not conducted to correct any deviations or inadequacies identified.    On 11/19/2019, at the Lavonia job site, the employer did not conduct a periodic inspection of the Lockout program to correct for deviations identified, including on TL10 Latex Line Ovens, the procedure did not include or address the residual heat energy or the length of time for the heat to dissipate or protective equipment needed to guard against the energy.
Recent events (2)
  • — I (O) $3280
  • — Z (S) $5470

1910.147 C06 I C

Serious Gravity 5 1 instance 10 exposed
Issued
Dec 3, 2019
Abate by
Jan 22, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i)(C): Where lockout was used for energy control, the periodic inspection did not include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected.  On 11/19/19, in the Lavonia facility manufacturing area, the employer did not ensure the Lockout/Tagout periodic inspection included a review between the inspector and each authorized employee, of the employee's responsibilities in that not all authorized employees were included in the review and some of the employees did not understand the procedural steps being reviewed and instead did not lockout equipment per the specific written procedures.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 C03

Serious Gravity 5 2 instances 3 exposed
Issued
Dec 3, 2019
Penalty
Initial $4,650 · Current $2,790 Reduced
29 CFR 1910.219(c)(3): Vertical or inclined shafting seven -7 feet or less from floor or working platform was not enclosed with stationary casing(s).    On 11/19/2019, at the Lavonia location at the TL10 line area, blending mixer motor shafts were not guarded and left exposed. The motors turn 1500-2000 rpm.
Recent events (2)
  • — I (S) $2790
  • — Z (S) $4650

1910.147 C07 I A

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 3, 2019
Abate by
Dec 30, 2019
Penalty
Initial $14,587 · Current $8,760 Reduced
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation.    On 11/19/19, at the Lavonia facility, the employer did not ensure employees performing service and maintenance to equipment at the facility were trained as authorized persons in the facility's Lockout program prior to conducting those activities.    Latexco, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.147(c)(7)(i)(A), which was contained in OSHA inspection number 1363634, citation number 1, item number 2 and was affirmed as a final order on 1/3/2019, with respect to a workplace located at 975 Gerrard Rd., Lavonia, Georgia.
Recent events (2)
  • — I (S) $8760
  • — Z (R) $14587

View Latexco, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344454996.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.