MIAMI, FL —
OSHA Inspection: MIDNIGHT EXPRESS POWER BOATS INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of MIDNIGHT EXPRESS POWER BOATS INC. in 351 NE 185TH STREET, MIAMI, FL 33179 (NAICS 336612). OSHA activity number 344456116.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MIDNIGHT EXPRESS POWER BOATS INC.
- Site address
- 351 NE 185TH STREET
- City
- MIAMI
- State
- FL
- ZIP
- 33179
- Mailing
- 351 NE 185TH STREET, MIAMI, FL 33179
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336612
- Employees
- 100
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.22 A01
- Issued
- Mar 20, 2020
- Abate by
- Apr 3, 2020
- Penalty
- Initial $8,906 · Current $4,453 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition: On or about 11/19/2019, at the finishing area of Midnight Express Power Boats Inc., 351 NE 185th St, Miami, FL 33179, employees were exposed to fire and explosion hazards while working in an area with explosive combustible dust accumulated on roof structure, electrical equipment, walls, workstations and floors.
Recent events (2)
- — I (S) $4453
- — Z (S) $8906
1910.133 A01
- Issued
- Mar 20, 2020
- Penalty
- Initial $5,937 · Current $2,969 Reduced
General-duty citation text
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: On or about 2/27/2020, at the finishing area of Midnight Express Power Boats Inc., 351 NE 185th St, Miami, FL 33179, an employee was exposed to a struck by hazard while wearing eye protection while grinding laminated boat parts.
Recent events (2)
- — I (S) $2968.5
- — Z (S) $5937
1910.242 A
- Issued
- Mar 20, 2020
- Abate by
- Mar 27, 2020
- Penalty
- Initial $5,937 · Current $2,969 Reduced
General-duty citation text
29 CFR 1910.242(a): Hand and portable powered tools or equipment were not kept in safe condition: On or about 2/27/2020, at the finishing area of Midnight Express Power Boats Inc., 351 NE 185th St, Miami, FL 33179, an employee was exposed to an electrical hazard while using a buffer (i.e. Makita, Serial number 56953A, Model 9237C) which had its cord spliced and covered with electrical tape.
Recent events (2)
- — I (S) $2968.5
- — Z (S) $5937
1910.307 C
- Issued
- Mar 20, 2020
- Abate by
- Apr 14, 2020
- Penalty
- Initial $8,906 · Current $4,453 Reduced
General-duty citation text
29 CFR 1910.307(c): Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location: On or about 11/19/2019, at the finishing area of Midnight Express Power Boats Inc., 351 NE 185th St, Miami, FL 33179, employees were exposed to fire and explosion hazards while working in an area with accumulated explosive combustible dust which lacked electrical equipment approved for a Class II, Division 2, which included, but not limited to; electrical conduits, enclosures, etc.
Recent events (2)
- — I (S) $4453
- — Z (S) $8906
1910.305 G02 III
- Issued
- Mar 20, 2020
- Abate by
- Mar 26, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: On or about 2/27/2020, at the finishing area of Midnight Express Power Boats Inc., 351 NE 185th St, Miami, FL 33179, an extension cord lacked strain relief at its female end attachment plug, exposing an employee to an electrical hazard.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Midnight Express Power Boats INC.
View Midnight Express Power Boats INC.'s full OSHA safety record →
More inspections in this industry (NAICS 336612)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344456116.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.