MIAMI, FL —
OSHA Inspection: MIDNIGHT EXPRESS POWER BOATS INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of MIDNIGHT EXPRESS POWER BOATS INC. in 351 NE 185TH STREET, MIAMI, FL 33179 (NAICS 336612). OSHA activity number 344457874.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MIDNIGHT EXPRESS POWER BOATS INC.
- Site address
- 351 NE 185TH STREET
- City
- MIAMI
- State
- FL
- ZIP
- 33179
- Mailing
- 351 NE 185TH STREET, MIAMI, FL 33179
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336612
- Employees
- 100
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.95 C01
- Issued
- Apr 6, 2020
- Abate by
- May 28, 2020
- Penalty
- Initial $9,446 · Current $4,723 Reduced
8111
General-duty citation text
29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.95(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent. a) On or about February 20, 2020, at the jobsite located at 351 NE 185th Street Miami, FL 33179, an employee working as a sander/buffer in lamination area was exposed to continuous noise at 76.6 % which exceeds the action level of 50% (an 8-hour time weighted average (TWA) sound level of 85 dBA for instituting a hearing conservation program. The 8-hour TWA sound level was approximately 88.2 dBA during the 427 minute sampling period. Exposure calculations included a zero increment for the 53 minutes not sampled. b) On or about February 20, 2020, at the jobsite located at 351 NE 185th Street Miami, FL 33179, an employee working as a sander/buffer in lamination area was exposed to continuous noise at 106.1% which exceeds the action level of 50% (an 8-hour time weighted average (TWA) sound level of 85 dBA for instituting a hearing conservation program. The 8-hour TWA sound level was approximately 90.4 dBA during the 428 minute sampling period. Exposure calculations included a zero increment for the 52 minutes not sampled.
Recent events (2)
- — I (S) $4723
- — Z (S) $9446
1910.134 D01 I
- Issued
- Apr 6, 2020
- Abate by
- Apr 23, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(d)(1)(i): The employer shall select and provide an appropriate respirator based on the respiratory hazard(s) to which the worker is exposed in the workplace and user factors that affect respirator performance and reliability. On or about February 20, 2020, at the jobsite located at 351 NE 185th Street Miami, FL 33179, the employer did not select appropriate type respirators for employees who had facial hair for religious purposes, were wearing 3M elastomeric half mask respirators while performing sanding/painting operations.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 G01 I B
- Issued
- Apr 6, 2020
- Abate by
- Apr 23, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(g)(1)(i)(B): Respirators with tight-fitting facepieces were worn by employees with a condition that interfered with the face-to-facepiece seal or valve function: On or about February 20, 2020, at the jobsite located at 351 NE 185th Street Miami, FL 33179, the employer did not ensure that employees correctly wore respirators in that employees were wearing respirators with the straps of the respirators on the outside of hoods for head covering. The wearing of a respirator in this manner prevents the respirators from forming an effective seal and allows the employee to inhale contaminants.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Midnight Express Power Boats INC.
View Midnight Express Power Boats INC.'s full OSHA safety record →
More inspections in this industry (NAICS 336612)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344457874.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.