Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MIDNIGHT EXPRESS POWER BOATS INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of MIDNIGHT EXPRESS POWER BOATS INC. in 351 NE 185TH STREET, MIAMI, FL 33179 (NAICS 336612). OSHA activity number 344457874.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Midnight Express Power Boats INC. — free Get an email when a new federal OSHA severe-injury report for Midnight Express Power Boats INC. is published. One employer, no account, unsubscribe in one click.
Site address
351 NE 185TH STREET
City
MIAMI
State
FL
ZIP
33179
Mailing
351 NE 185TH STREET, MIAMI, FL 33179
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336612
Employees
100
Ownership type
A

3 citations on file for this inspection.

1910.95 C01

Serious Gravity 10 2 instances 2 exposed
Issued
Apr 6, 2020
Abate by
May 28, 2020
Penalty
Initial $9,446 · Current $4,723 Reduced

Hazardous substances 8111

29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.95(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent.    a) On or about February 20, 2020, at the jobsite located at 351 NE 185th Street Miami, FL 33179, an employee working as a sander/buffer in lamination area was exposed to continuous noise at 76.6 % which exceeds the action level of 50% (an 8-hour time weighted average (TWA) sound level of 85 dBA for instituting a hearing conservation program. The 8-hour TWA sound level was approximately 88.2 dBA during the 427 minute sampling period.  Exposure calculations included a zero increment for the 53 minutes not sampled.    b) On or about February 20, 2020, at the jobsite located at 351 NE 185th Street Miami, FL 33179, an employee working as a sander/buffer in lamination area was exposed to continuous noise at 106.1% which exceeds the action level of 50% (an 8-hour time weighted average (TWA) sound level of 85 dBA for instituting a hearing conservation program. The 8-hour TWA sound level was approximately 90.4 dBA  during the 428 minute sampling period.  Exposure calculations included a zero increment for the 52 minutes not sampled.
Recent events (2)
  • — I (S) $4723
  • — Z (S) $9446

1910.134 D01 I

Other-than-serious 1 instance 2 exposed
Issued
Apr 6, 2020
Abate by
Apr 23, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.134(d)(1)(i): The employer shall select and provide an appropriate respirator based on the respiratory hazard(s) to which the worker is exposed in the workplace and user factors that affect respirator performance and reliability.  On or about February 20, 2020, at the jobsite located at 351 NE 185th Street Miami, FL 33179, the employer did not select appropriate type respirators for employees who had facial hair for religious purposes, were wearing 3M elastomeric half mask respirators while performing sanding/painting operations.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 G01 I B

Other-than-serious 1 instance 4 exposed
Issued
Apr 6, 2020
Abate by
Apr 23, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.134(g)(1)(i)(B): Respirators with tight-fitting facepieces were worn by employees with a condition that interfered with the face-to-facepiece seal or valve function:  On or about February 20, 2020, at the jobsite located at 351 NE 185th Street Miami, FL 33179, the employer did not ensure that employees correctly wore respirators in that employees were wearing respirators with the straps of the respirators on the outside of hoods for head covering. The wearing of a respirator in this manner prevents the respirators from forming an effective seal and allows the employee to inhale contaminants.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Midnight Express Power Boats INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344457874.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.