Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NEWMAN TECHNOLOGY, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of NEWMAN TECHNOLOGY, INC. in 100 CAIRNS RD., MANSFIELD, OH 44903 (NAICS 336399). OSHA activity number 344492384.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Newman Technology, INC. — free Get an email when a new federal OSHA severe-injury report for Newman Technology, INC. is published. One employer, no account, unsubscribe in one click.
Site address
100 CAIRNS RD.
City
MANSFIELD
State
OH
ZIP
44903
Mailing
100 CAIRNS RD., MANSFIELD, OH 44903
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336399
Employees
803
Ownership type
A

3 citations on file for this inspection.

1910.147 C07 I A

Serious Gravity 5 2 instances 2 exposed
Issued
Mar 13, 2020
Penalty
Initial $10,603 · Current $10,603
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation:  A)     Newman Technology, Inc., located at 100 Cairns Road, Mansfield, OH 44903: On or about December 5, 2019, the employer did not adequately train employees to lockout/tagout equipment such as, but not limited to, the Flex Tube Comp (Flex 30) machine (Model # MS14002-5) located in the 1215 Flex Tube Assembly Department. Employees did not control all hazardous energy sources such as, but not limited to, electrical and pneumatic before removing parts that were not ejected onto the chute. Employees were exposed to struck-by and pinch point hazards that could result in serious injuries.  B)     Newman Technology, Inc., located at 100 Cairns Road, Mansfield, OH 44903: On or about December 5, 2019, the employer did not adequately train employees to lockout/tagout equipment such as, but not limited to, the Flex Tube Comp (Flex 30) machine (Model # MS14002-5) located in the 1215 Flex Tube Assembly Department. Employees did not power down the equipment using established procedures and did not verify that all hazardous energy sources such as, but not limited to, electrical were isolated before cleaning inside the machine. Employees were exposed to struck-by and pinch point hazards that could result in serious injuries.
Recent events (1)
  • — Z (S) $10603

1910.147 D

Serious Gravity 5 2 instances 2 exposed
Issued
Mar 13, 2020
Penalty
Initial $10,603 · Current $10,603
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):   A)     Newman Technology, Inc., located at 100 Cairns Road, Mansfield, OH 44903: On or about December 5, 2019, the employer did not ensure that all the steps outlined in 29 CFR 1910.147(d), required for the control of the hazardous energy sources, were performed. Employees did not control all hazardous energy sources such as, but not limited to, electrical and pneumatic on the Flex Tube Comp (Flex 30) machine (Model # MS14002-5), located in the 1215 Flex Tube Assembly Department, before removing parts that were not ejected onto the chute. Employees were exposed to struck-by and pinch point hazards that could result in serious injuries.  B)     Newman Technology, Inc., located at 100 Cairns Road, Mansfield, OH 44903: On or about December 5, 2019, the employer did not ensure that all the steps outlined in 29 CFR 1910.147(d), required for the control of the hazardous energy sources, were performed. Employees did not power down the Flex Tube Comp (Flex 30) machine (Model # MS14002-5), located in the 1215 Flex Tube Assembly Department, using established procedures and did not verify that all hazardous energy sources such as, but not limited to, electrical were isolated before cleaning inside the machine. Employees were exposed to struck-by and pinch point hazards that could result in serious injuries.
Recent events (1)
  • — Z (S) $10603

1910.212 A01

Serious Gravity 10 1 instance 10 exposed
Issued
Mar 13, 2020
Penalty
Initial $13,494 · Current $13,494
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  A)     Newman Technology, Inc., located at 100 Cairns Road, Mansfield, OH 44903: On or about December 5, 2019, the employer did not ensure that one or more methods of adequate machine guarding were provided to protect employees from hazards such as, but not limited to, the pinch point created between the fixtures ejector and the fixture on the Flex Tube Comp (Flex 30) machine (Model # MS14002-5) located in the 1215 Flex Tube Assembly Department. Employees were exposed to pinch point hazards that could result in amputations.
Recent events (1)
  • — Z (S) $13494

View Newman Technology, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344492384.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.