Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HAC ROOFING LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HAC ROOFING LLC in 21157 SADDLEBACK CIR, PARKER, CO 80138 (NAICS 238160). OSHA activity number 344497102.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch HAC Roofing LLC — free Get an email when a new federal OSHA severe-injury report for HAC Roofing LLC is published. One employer, no account, unsubscribe in one click.
Establishment
HAC ROOFING LLC
Site address
21157 SADDLEBACK CIR
City
PARKER
State
CO
ZIP
80138
Mailing
6965 E 33RD AVE, DENVER, CO 80207
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
7
Ownership type
A

3 citations on file for this inspection.

1926.102 A01

Serious Gravity 1 1 instance 2 exposed
Issued
Jan 7, 2020
Abate by
Jan 17, 2020
Penalty
Initial $1,875 · Current $1,875
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation:  (a) On or about December 6, 2019, and at times prior, HAC Roofing LLC did not ensure that employees were protected from eye injuries due to flying particles while using pneumatic nail guns to place roofing shingles.  Abatement Note: Abatement certification is required for this item (See enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
  • — Z (S) $1875

1926.1053 B01

Serious Gravity 1 1 instance 7 exposed
Issued
Jan 7, 2020
Penalty
Initial $1,875 · Current $1,875
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  (a) On or about December 6, 2019, the employer did not ensure that ladders being utilized to access a residential roof were extended at least 3 feet above the landing surface.  Abatement Note: Abatement certification is required for this item (See enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
  • — Z (S) $1875

1926.501 B13

Repeat Gravity 10 1 instance 7 exposed
Issued
Jan 7, 2020
Abate by
Jan 27, 2020
Penalty
Initial $21,879 · Current $21,879
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   (a) On or about December 6, 2019, HAC Roofing LLC did not ensure that employees conducting re-roofing operations on a single-family residential home at 21157 Saddleback Cir., Parker, CO 80138 were protected from fall hazards greater than 9 feet.   HAC Roofing LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501, Duty to have fall protection, which was contained in OSHA inspection number 1358473, citation number 1, item number 1 and was affirmed as a final order on 01/29/2019, with respect to a workplace located at 6493 Killarney Ct., Aurora, CO 80239.  HAC Roofing LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501, Duty to have fall protection, which was contained in OSHA inspection number 1264540, citation number 1, item number 1 and was affirmed as a final order on 10/05/2017, with respect to a workplace located at 5025 Lowell Blvd., Denver, CO 80221.  HAC Roofing LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501, Duty to have fall protection, which was contained in OSHA inspection number 1172573, citation number 1, item number 1 and was affirmed as a final order on 10/14/2016, with respect to a workplace located at 5386 Barnstormers Ave., Colorado Springs, CO 80911.  HAC Roofing LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501, Duty to have fall protection, which was contained in OSHA inspection number 1172491, citation number 1, item number 1 and was affirmed as a final order on 10/14/2016, with respect to a workplace located at 1130 Modell Dr., Colorado Springs, CO 80911.  Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
  • — Z (R) $21879

View HAC Roofing LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344497102.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.