MORAINE, OH —
OSHA Inspection: FUYAO GLASS AMERICA, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of FUYAO GLASS AMERICA, INC. in 800 FUYAO AVENUE, MORAINE, OH 45439 (NAICS 327215). OSHA activity number 345461198.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FUYAO GLASS AMERICA, INC.
- Site address
- 800 FUYAO AVENUE
- City
- MORAINE
- State
- OH
- ZIP
- 45439
- Mailing
- 800 FUYAO AVENUE, MORAINE, OH 45439
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327215
- Employees
- 1764
- Ownership type
- A
Citations
11 citations on file for this inspection.
1910.37 A02
- Issued
- Dec 2, 2021
- Abate by
- Dec 29, 2021
- Penalty
- Initial $13,653 · Current $0 Reduced
General-duty citation text
29 CFR 1910.37(a)(2): Exit routes must be arranged so that employees will not have to travel toward a high hazard area, unless the path of travel is effectively shielded from the high hazard area by suitable partitions or other physical barriers. (a) On or about July 17, 2021 during an emergency evacuation, employees exited through door S2 at the direction of their supervisor, as it was the closest exit to the outdoor rally points for the ARG Packaging area, even though the source of the gas leak was at the overhead garage door at location S2, and the exit door not shielded from the hazards of a gas leak and potential fire or explosion.
Recent events (2)
- — I (S) $0
- — Z (S) $13653
1910.37 E
- Issued
- Dec 2, 2021
- Abate by
- Dec 29, 2021
- Penalty
- Initial $10,728 · Current $0 Reduced
General-duty citation text
29 CFR 1910.37(e): An employee alarm system must be operable. Employers must install and maintain an operable employee alarm system that has a distinctive signal to warn employees of fire or other emergencies, unless employees can promptly see or smell a fire or other hazard in time to provide adequate warning to them. The employee alarm system must comply with �� 1910.165. (a) On or about July 17, 2021, the Simplex 4100-9311 alarm system was not activated to warn employees of the need to evacuate due to a gas leak near door S2 and the overhead garage door in the ARG packaging area. Many employees reported they could not smell the gas leak immediately due to wearing face masks to comply with the employer's COVID-19 pandemic policy.
Recent events (2)
- — I (S) $0
- — Z (S) $10728
1910.38 D
- Issued
- Dec 2, 2021
- Abate by
- Dec 29, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.38(d): Employee alarm system. An employer must have and maintain an employee alarm system. The employee alarm system must use a distinctive signal for each purpose and comply with the requirements in �� 1910.165. (a) On or about July 17, 2021, the Simplex 4100-9311 alarm system was not activated to warn employees of the need to evacuate due to a gas leak near door S2 and the overhead garage door in the ARG packaging area. Many employees reported they could not smell the gas leak immediately due to wearing face masks to comply with the employer's COVID-19 pandemic policy.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.165 B01
- Issued
- Dec 2, 2021
- Abate by
- Dec 29, 2021
- Penalty
- Initial $0 · Current $2,500
General-duty citation text
29 CFR 1910.165(b)(1): The employee alarm system shall provide warning for necessary emergency action as called for in the emergency action plan, or for reaction time for safe escape of employees from the workplace or the immediate work area, or both. (a) On or about July 17, 2021, the Simplex 4100-9311 alarm system was not activated to warn employees of the need to evacuate due to a gas leak near door S2 and the overhead garage door in the ARG packaging area. Many employees reported they could not smell the gas leak immediately due to wearing face masks to comply with the employer's COVID-19 pandemic policy.
Recent events (2)
- — I (O) $2500
- — Z (S) $0
1910.165 B05
- Issued
- Dec 2, 2021
- Abate by
- Dec 29, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.165(b)(5): The employer shall establish procedures for sounding emergency alarms in the workplace. For those employers with 10 or fewer employees in a particular workplace, direct voice communication is an acceptable procedure for sounding the alarm provided all employees can hear the alarm. Such workplaces need not have a back-up system. (a) On or about July 17, 2021, the employer had not established and implemented procedures for sounding the Simplex 4100-9311 alarm system to evacuate the building in case of a gas leak that could not be immediately stopped.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.38 E
- Issued
- Dec 2, 2021
- Abate by
- Dec 29, 2021
- Penalty
- Initial $10,728 · Current $10,728
General-duty citation text
29 CFR 1910.38(e): Training. An employer must designate and train employees to assist in a safe and orderly evacuation of other employees. On or about July 17, 2021, the employer had not trained supervisors and other designated employees in the safe and orderly evacuation of the facility during an emergency when the gas pipe to the overhead dock heater in the ARG packaging area developed a gas leak after being struck by a powered industrial truck, in that: (a) Employees exited through door S2 at the direction of their supervisor as it was the closest exit to the outdoor rally points for the ARG Packaging area, even though the source of the gas leak was at the overhead garage door nearest location S2, and the exit door was not shielded from the hazards of a gas leak and potential fire or explosion. (b) Some unidentified employees were observed by their co-workers lighting cigarettes as soon as they exited through the ARG overhead door while the gas leak was occurring. (c) Some employees were left at their workstations and were not notified in a timely manner of the gas leak and the need to evacuate until the gas could be turned off. (d) Kenny Sprow, senior EHS manager, Taylor Guntle, maintenance supervisor, and two maintenance employees monitored the air with four gas meters while they searched for the shut off for the gas. It took approximately 15 minutes to determine they could not find the correct shut off and approximately 45 minutes to trace the gas line from inside the building and on the roof to locate the correct shut off valve. No members of management or EHS employees activated the alarms to have employees evacuate during that time.
Recent events (2)
- — I (O) $10728
- — Z (S) $10728
1910.39 C01
- Issued
- Dec 2, 2021
- Abate by
- Dec 29, 2021
- Penalty
- Initial $10,728 · Current $0 Reduced
General-duty citation text
29 CFR 1910.39(c)(1): A list of all major fire hazards, proper handling and storage procedures for hazardous materials, potential ignition sources and their control, and the type of fire protection equipment necessary to control each major hazard; (a) On or about July 17, 2021, the employer's fire prevention plan did not include a list of all major fire hazards, such as but not limited to a gas leak from the gas powered heaters located at the overhead doors in the production area.
Recent events (2)
- — I (S) $0
- — Z (S) $10728
1910.39 C03
- Issued
- Dec 2, 2021
- Abate by
- Dec 29, 2021
- Penalty
- Initial $10,728 · Current $0 Reduced
General-duty citation text
29 CFR 1910.39(c)(3): Procedures for regular maintenance of safeguards installed on heat-producing equipment to prevent the accidental ignition of combustible materials; (a) On or about July 17, 2021, the employer had not established and implemented procedures for the regular maintenance of the shut off valves for the overhead gas powered heaters that were located at the overhead doors in the production area, in that maintenance employees took more that 45 minutes to locate and shut off the gas to the heater in the ARG packaging area when a powered industrial truck struck the gas pipe causing a gas leak.
Recent events (2)
- — I (S) $0
- — Z (S) $10728
1904.40 A
- Issued
- Dec 2, 2021
- Penalty
- Initial $2,146 · Current $1,000 Reduced
General-duty citation text
29 CFR 1904.40(a): Basic requirement. When an authorized government representative asks for the records you keep under Part 1904, you must provide copies of the records within four (4) business hours. a) Copies of the OSHA 300 logs and summaries for the calendar years 2019, 2020 and the 300 log for 2021 year to date were not provided within four hours of the request.
Recent events (2)
- — I (O) $1000
- — Z (O) $2146
1910.38 C06
- Issued
- Dec 2, 2021
- Abate by
- Dec 21, 2021
- Penalty
- Initial $1,205 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.38(c)(6): The name or job title of every employee who may be contacted by employees who need more information about the plan or an explanation of their duties under the plan. (a) On or about July 17, 2021 the employer had not updated the names and contact information in the emergency action plan, as the contact names listed for the EHS department were both no longer employed by Fuyao.
Recent events (2)
- — I (O) $1000
- — Z (O) $1205
1910.145 D02
- Issued
- Dec 2, 2021
- Abate by
- Jan 21, 2022
- Penalty
- Initial $1,205 · Current $0 Reduced
General-duty citation text
29 CFR 1910.145(d)(2): Danger signs. The colors red, black, and white shall be those of opaque glossy samples as specified in Table 1 of Fundamental Specification of Safety Colors for CIE Standard Source "C", American National Standard Z53.1-1967, which is incorporated by reference as specified in Sec. 1910.6. (a) On or about July 17, 2021 a powered industrial truck operator struck the gas piping at the overhead dock heater in the ARG Packaging Area, causing a gas leak. The PIT operator was only aware of the gas leak when they smelled gas, as the employer had not posted Danger signs to notify workers of the overhead hazard in an area where PITs were used to place boxes of supplies on storage shelves.
Recent events (2)
- — I (O) $0
- — Z (O) $1205
More inspections at Fuyao Glass America, INC.
View Fuyao Glass America, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 327215)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345461198.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.