Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SMITHBRIDGE GUAM, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SMITHBRIDGE GUAM, INC. in 300 CHALAN PADIRON HAYA, YIGO, GU 96929 (NAICS 212312). OSHA activity number 345762389.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Smithbridge Guam, INC. — free Get an email when a new federal OSHA severe-injury report for Smithbridge Guam, INC. is published. One employer, no account, unsubscribe in one click.
Site address
300 CHALAN PADIRON HAYA
City
YIGO
State
GU
ZIP
96929
Mailing
P.O. BOX 11700, YIGO, GU 96929
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
212312
Employees
90
Ownership type
A

5 citations on file for this inspection.

1910.212 A01

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 16, 2022
Abate by
Apr 26, 2022
Penalty
Initial $5,283 · Current $3,698 Reduced
29 CFR  1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  In the warehouse fabrication area: A Zay milling machine used by employees to fabricate and repair parts was not equipped with a chuck guard. Employees were exposed to rotating part hazards.
Recent events (2)
  • — I (S) $3698
  • — Z (S) $5283

1910.253 B04 III

Deleted Serious Gravity 1 2 instances 6 exposed
Issued
Mar 16, 2022
Abate by
Mar 28, 2022
Penalty
Initial $5,283 · Current $0 Reduced
29 CFR  1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet:  In the Fabrication Shop: Oxygen and Acetylene cylinders that were not in use, were stored together. Employees were exposed to fire hazards.  at the Warehouse Cylinder Storage: Oxygen and Acetylene cylinders that were not in use, were stored together. Employees were exposed to fire hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5283

1910.157 E03

Deleted Other-than-serious 2 instances 5 exposed
Issued
Mar 16, 2022
Abate by
Mar 28, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check:  In the warehouse furniture store area:  The portable fire extinguisher available to employee for fighting incipient fires was not checked annually.  Employees were exposed to fire hazards.  In the sign shop: The portable fire extinguisher available to employee for fighting incipient fires was not checked annually. Employees were exposed to fire hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 A02 IX

Other-than-serious 1 instance 1 exposed
Issued
Mar 16, 2022
Abate by
Mar 28, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.305(a)(2)(ix): Lamps for general illumination were not protected from accidental contact or breakage by a suitable fixture or lampholder with a guard  In the Sign Shop: The overhead fluorescent lighting had exposed light tubes 4-feet above the worktable. Employees were exposed to laceration hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 C04

Other-than-serious 1 instance 4 exposed
Issued
Mar 16, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.305(c)(4): Faceplates for flush-mounted snap switches. Snap switches mounted in boxes did not have faceplates installed so as to completely cover the opening and seat against the finished surface:  In the Warehouse Furniture Store:  The faceplate for the light switch above the fire extinguisher was missing. Employees were exposed to electrical hazards.