Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: UFP BLANCHESTER, LLC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of UFP BLANCHESTER, LLC. in 940 CHERRY STREET, BLANCHESTER, OH 45107 (NAICS 321920). OSHA activity number 345815658.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch UFP Blanchester, LLC. — free Get an email when a new federal OSHA severe-injury report for UFP Blanchester, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
940 CHERRY STREET
City
BLANCHESTER
State
OH
ZIP
45107
Mailing
940 CHERRY STREET, BLANCHESTER, OH 45107
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321920
Employees
120
Ownership type
A

4 citations on file for this inspection.

1910.242 A

Deleted Serious Gravity 10 4 instances 4 exposed
Issued
Aug 19, 2022
Abate by
Sep 8, 2022
Penalty
Initial $14,502 · Current $0 Reduced
29 CFR  1910.242(a): Hand and portable powered tools and equipment, general. General requirements. Each employer shall be responsible for the safe condition of tools and equipment used by employees, including tools and equipment which may be furnished by employees.  a) On or before 02/21/2022, the employer did not ensure that employees operating the Everwin Pneumatic Coil Nailer PN65, PN70 and/or PN80 to manufacture wooden pallets while employees held down the trigger when a stuck nail misfired into parts of their bodies such as but not limited to the left wrist.     b) On or before 05/18/2022, the employer did not ensure that employees operating the Everwin Pneumatic Coil Nailer PN65, PN70 and/or PN80 were not administering constant pressure on the trigger for the nailer to prevent firing the nail guns nails from firing into parts of their bodies such as but not limited to the left wrist.     c) On or before 05/24/2022, the employer did not ensure that employees operating the Everwin Pneumatic Coil Nailer PN65, PN70 and/or PN80 were properly placing the nail gun against the wood pallet prior to firing the nail gun to prevent firing the nail guns nails from firing into parts of their bodies such as but not limited to the left middle finger.      d) On or before 06/06/2022, the employer did not ensure that employees operating the Everwin Pneumatic Coil Nailer PN65, PN70 and/or PN80 were not administering constant pressure on the trigger and placing portions of their bodies such as but not limited to (free hand) on the the wood during manufacturing exposing parts of their bodies such as but not limited to the left wrist to injury when the wood breaks where their free hand is located.
Recent events (3)
  • — F (S) $0
  • — C (S) $14502
  • — Z (S) $14502

1910.243 D02 I A

Deleted Serious Gravity 10 3 instances 3 exposed
Issued
Aug 19, 2022
Abate by
Sep 8, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.243(d)(2)(i)(a): The muzzle end of the tool shall have a protective shield or guard at least 3 1/2 inches in diameter, mounted perpendicular to and concentric with the barrel, and designed to confine any flying fragments or particles that might otherwise create a hazard at the time of firing.  a) On or about February 21, 2022, the employer did not ensure that the Everwin Pneumatic Coil Nailer PN65, PN70, PN80 used by employees to manufacture wooden pallets maintained  the work piece contact attachment in place.   b) On or about May 18, 2022, the employer did not ensure that the Everwin Pneumatic Coil Nailer PN65, PN70, PN80 used by employees to manufacture wooden pallets maintained  the work piece contact attachment in place.   c) On or about June 06, 2022, the employer did not ensure that the Everwin Pneumatic Coil Nailer PN65, PN70, PN80 used by employees to manufacture wooden pallets maintained  the work piece contact attachment in place.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.243 D02 I D 2

Serious Gravity 10 2 instances 2 exposed
Issued
Aug 19, 2022
Abate by
Feb 28, 2024
Penalty
Initial $0 · Current $7,251
29 CFR  1910.243(d)(2)(i)(d)(2): Firing of the tool shall be dependent upon at least two separate and distinct operations of the operator, with the final firing movement being separate from the operation of bringing the tool into the firing position.  a)On or about May 18, 2022, the employer did not ensure that the firing of the Everwin Pneumatic Coil Nailer PN65, PN70, PN80 require at least two separate and distinct operations of the operator in that employees were maintaining their fingers on the trigger for constant pressure and the work piece contact attachment was not present for at least one of the two separate and distinct operations.   b) On or about June 06, 2022, the employer did not ensure that the firing of the Everwin Pneumatic Coil Nailer PN65, PN70, PN80 require at least two separate and distinct operations of the operator in that employees were maintaining their fingers on the trigger for constant pressure and the work piece contact attachment was not present for at least one of the two separate and distinct operations.
Recent events (3)
  • — F (S) $7251
  • — C (S) $0
  • — Z (S) $0

1910.243 D04 XIII

Deleted Serious Gravity 10 4 instances 4 exposed
Issued
Aug 19, 2022
Abate by
Sep 8, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.243(d)(4)(xiii): All tools shall be used with the correct shield, guard, or attachment recommended by the manufacturer.  a) On or about June 09, 2022, the employer did not ensure that the Everwin pneumatic coil nailer PN65, PN70, PN80 shown to OSHA had the correct shield or guard or work piece contact attachment recommended by the manufacturer.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

View UFP Blanchester, LLC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345815658.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.