OSHA Inspection: SPRINGS FABRICATION, INC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SPRINGS FABRICATION, INC in 850 AEROPLAZA DR, COLORADO SPRINGS, CO 80916 (NAICS 332312). OSHA activity number 345923080.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Springs Fabrication, INC — free Get an email when a new federal OSHA severe-injury report for Springs Fabrication, INC is published. One employer, no account, unsubscribe in one click.
Site address
850 AEROPLAZA DR
City
COLORADO SPRINGS
State
CO
ZIP
80916
Mailing
850 AEROPLAZA DR, COLORADO SPRINGS, CO 80916
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
102
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 15, 2022
Abate by
Jul 27, 2022
Penalty
Initial $13,052 · Current $6,526 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees while raising and positioning a load using a Close Proximity Operated Manually Controlled Permanent Magnet:  a) Hydro Shop: On or about April 1, 2022, workers were exposed to crushing injuries while using a magnetic lifting device rated at 250 pounds to lift and position a flange blank weighing 298 pounds onto a pressure vessel flange opening.  The magnet was not rated for the load in that the rated capacity was 250 pounds and the load, a flange blank, weighed  298 pounds.  A side pull occurred when the flange blank caught on a receiving lug.  This created a side pull force that disengaged the magnet from the flange blank, which then fell into position while the operator's finger was resting on the mating surface.