Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GASBARRE PRODUCTS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of GASBARRE PRODUCTS, INC. in 310 STATE STREET, SAINT MARYS, PA 15857 (NAICS 333994). OSHA activity number 345940704.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Gasbarre Products, INC. — free Get an email when a new federal OSHA severe-injury report for Gasbarre Products, INC. is published. One employer, no account, unsubscribe in one click.
Site address
310 STATE STREET
City
SAINT MARYS
State
PA
ZIP
15857
Mailing
310 STATE STREET, SAINT MARYS, PA 15857
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
333994
Employees
52
Ownership type
A

17 citations on file for this inspection.

1910.37 A03

Serious Gravity 5 1 instance 52 exposed
Issued
Sep 30, 2022
Abate by
Oct 27, 2022
Penalty
Initial $7,458 · Current $3,500 Reduced
29 CFR  1910.37(a)(3):Exit route(s) were not kept free and unobstructed:  a.) Gasbarre Products, Inc.; on or about 5/5/2022 and at times prior thereto, Bay 1 North side emergency exit route was obstructed by materials, pallets, and carts.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $7458

1910.37 A01

Serious Gravity 5 1 instance 6 exposed
Issued
Sep 30, 2022
Abate by
Oct 27, 2022
Penalty
Initial $0 · Current $0

Hazardous substances 1340

29 CFR  1910.37(a)(1):Exit routes shall not have flammable, explosive, combustible gases or flammable furnishings stored in the exit route.  a.) Gasbarre Products, Inc.; on or about 5/5/2022 and at times prior thereto, Bay 4 West side exit route had flammables stored in the exit route. Containers of flammable and combustible materials including but not limited to gasoline, paints, and oils were stored on the floor outside of flammable storage cabinets.  There was no space remaining within the flammable cabinets, so employees used the area around the cabinet for storage of additional containers of flammable and combustible liquids.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.22 A01

Serious Gravity 5 1 instance 6 exposed
Issued
Sep 30, 2022
Abate by
Oct 27, 2022
Penalty
Initial $7,458 · Current $3,500 Reduced
29 CFR  1910.22(a)(1): The employer did not ensure that all places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition.   a.) Gasbarre Products, Inc.; on or about 5/5/2022 and at times prior thereto, Materials including but not limited to a coolant hose and an air hose were stored in an aisleway in the North side of Bay 4.  Employees were exposed to slip trip and fall hazards while walking through the area.  b.) Gasbarre Products, Inc.; on or about 5/5/2022 and at times prior thereto, Isle ways in bay 4 were obstructed by debris and other material exposing employees to potential trip hazards while walking through bay 4 of the shop.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $7458

1910.176 C

Serious Gravity 5 1 instance 6 exposed
Issued
Sep 30, 2022
Abate by
Oct 27, 2022
Penalty
Initial $0 · Current $0

Hazardous substances 1340

29 CFR  1910.176(c):Storage areas were not kept free from accumulation of materials that constituted hazards from tripping, fire, explosion or pest harborage:  a.) Gasbarre Products, Inc.; on or about 5/5/2022 and at times prior thereto, Bay 4 West side flammable storage location had numerous flammables including but not limited to paints, gas, and hydraulic fluid stored both in and around flammable storage cabinets with the doors open.  b) Gasbarre Products, Inc.; on or about 5/5/2022 and at times prior thereto, Storage areas in bay 4 on the East side of the structure were not kept free of accumulation of material next to an electrical panel resulting in potential fire hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.101 B

Serious Gravity 5 3 instances 52 exposed
Issued
Sep 30, 2022
Abate by
Oct 27, 2022
Penalty
Initial $11,188 · Current $10,000 Reduced
29 CFR  1910.101(b):The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6: 5.8.4 Cylinder positions in storage: All compressed gas cylinders in service or in storage at user locations shall be secured to prevent falling or rolling.  a.) Gasbarre Products, Inc.; on or about 5/5/2022 and at times prior thereto, CNC plasma table area-  2 compressed argon and oxygen mixture gas cylinders were free standing and not secured while in storage during the inspection.   b.) Gasbarre Products, Inc.; on or about 5/5/2022 and at times prior thereto, Safety signage storage area-  One compressed N.O.S. gas cylinder was free standing and not secured while in storage next to the safety sign storage area during the inspection.   c.) Gasbarre Products, Inc.; on or about 5/5/2022 and at times prior thereto, Bay 1 North side area- One compressed N.O.S. gas cylinder was free standing and not secured while in storage next to a welder during the inspection.
Recent events (2)
  • — I (S) $10000
  • — Z (S) $11188

1910.253 B02 IV

Serious Gravity 5 1 instance 6 exposed
Issued
Sep 30, 2022
Abate by
Oct 27, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.253(b)(2)(iv):Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use:  a.) Gasbarre Products, Inc.; on or about 5/5/2022 and at times prior thereto, Bay 1 North side- One compressed oxygen gas cylinder was not in use and did not have a valve protection cap in place.  b.) Gasbarre Products, Inc.; on or about 5/5/2022 and at times prior thereto, CNC Plasma Table Area- One compressed oxygen gas cylinder was not in use and did not have a valve protection cap in place.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 P01

Serious Gravity 5 1 instance 52 exposed
Issued
Sep 30, 2022
Abate by
Oct 27, 2022
Penalty
Initial $11,188 · Current $8,000 Reduced
29 CFR  1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been  taken out of service until restored to safe operating condition.   a.) Gasbarre Products, Inc.; on or about 5/5/2022 and at times prior thereto, Employees periodically operated a Hyster 70 forklift that had a damaged seatbelt system which prevented use of the seatbelt.  b.) Gasbarre Products, Inc. Bay 2 area; on or about 5/5/2022 and at times prior thereto, employees operate a Hyster 70 propane forklift in various areas of the facility throughout each work shift. The tires on the powered industrial truck were damaged in that they were missing large chunks of tire material.
Recent events (2)
  • — I (S) $8000
  • — Z (S) $11188

1910.178 L01 I

Serious Gravity 5 2 instances 50 exposed
Issued
Sep 30, 2022
Abate by
Oct 27, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.178(l)(1)(i):The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):  a.) Gasbarre Products, Inc.; on or about 5/5/2022 and at times prior thereto, employees are authorized to operate a Hyster 70 forklift without completing a training and evaluation in the Bay 4 area.  b.) Gasbarre Products, Inc.; on or about 7/12/2022 and at times prior thereto, employees are authorized to operate a Hyster 70 forklift without completing a training and evaluation in the Bay 1 area.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G01 II

Serious Gravity 5 16 instances 52 exposed
Issued
Sep 30, 2022
Abate by
Oct 27, 2022
Penalty
Initial $9,324 · Current $2,000 Reduced
29 CFR  1910.303(g)(1)(ii):The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  a.) Gasbarre Products, Inc.; on or about 5/5/2022 and at times prior thereto, The areas directly in of the front 240V and 480V electrical panels and disconnects located throughout the facility  were blocked due to the areas being used for storage of miscellaneous supplies and equipment. The electrical panels and disconnects energized including but not limited to; shop lighting, equipment, and cranes.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $9324

1910.147 C06 I

Serious Gravity 5 5 instances 5 exposed
Issued
Sep 30, 2022
Abate by
Oct 27, 2022
Penalty
Initial $7,458 · Current $2,000 Reduced
29 CFR  1910.147(c)(6)(i):The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  a.) Gasbarre Products, Inc.; on or about 5/5/2022 and at times prior thereto, employees conducted servicing and maintenance work on machines and equipment that included but was not limited to press brakes.  Annual periodic inspections of the lockout/ tagout procedures (energy control procedures) had not been conducted.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $7458

1910.147 C06 II

Serious Gravity 5 5 instances 5 exposed
Issued
Sep 30, 2022
Abate by
Oct 27, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed:  a.) Gasbarre Products, Inc.; on or about 5/5/2022 and at times prior thereto, employees perform servicing and maintenance of equipment Including but not limited to Press Brakes.  The employer did not certify that periodic inspections of the energy control procedures had been performed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C07 I

Serious Gravity 5 2 instances 52 exposed
Issued
Sep 30, 2022
Abate by
Oct 27, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(7)(i):The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees:  a.) Gasbarre Products, Inc.; on or about 5/5/2022 and at times prior thereto, Employees conduct servicing and maintenance on equipment including but not limited to, Press Brakes.  The employer did not conduct Lockout Tagout/Hazardous Energy Control training with Authorized employees.  b.) Gasbarre Products, Inc.; on or about 5/5/2022 and at times prior thereto, Employees operate Press Brake equipment which requires periodic service maintenance and repairs.  The employer did not conduct Lockout Tagout/Hazardous Energy Control training with Affected employees.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C07 IV

Serious Gravity 5 1 instance 52 exposed
Issued
Sep 30, 2022
Abate by
Oct 27, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(7)(iv):The employer had not certified that employee training had been accomplished and kept up to date:  a.) Gasbarre Products, Inc.; on or about 5/5/2022 and at times prior thereto, employees perform service and maintenance of equipment. The employer did not certify that Lockout Tagout/Hazardous Energy Control training had been performed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C04 I

Serious Gravity 5 1 instance 5 exposed
Issued
Sep 30, 2022
Abate by
Oct 27, 2022
Penalty
Initial $7,458 · Current $2,000 Reduced
29 CFR  1910.147(c)(4)(i):Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  a.) Gasbarre Products, Inc.; on or about 5/5/2022 and at times prior thereto, employees performed servicing and maintenance work on machines that included but were not limited to the Cincinnati 600H and Pacific 300 ton hydraulic press brakes.  Specific energy control procedures had not been developed for employees to utilize when performing servicing and maintenance on machines.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $7458

1910.333 B02 I

Serious Gravity 5 5 instances 5 exposed
Issued
Sep 30, 2022
Abate by
Oct 27, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.333(b)(2)(i):The employer did not maintain a written copy of the procedures outlined in paragraph (b)(2) of 29 CFR 1910.333 and did not make it available for inspection by the Assistant Secretary of Labor and his or her authorized representatives:  a.) Gasbarre Products, Inc.; on or about 5/5/2022 and at times prior thereto, Employer had not developed electrical lockout tagout procedures. Employees perform lockout tagout on electrical panels and disconnects.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.332 B01

Serious Gravity 5 5 instances 5 exposed
Issued
Sep 30, 2022
Abate by
Oct 27, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.332(b)(1):Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments:  a.) Gasbarre Products, Inc.; on or about 5/5/2022 and at times prior thereto, Employees do not have electrical lockout tagout training. Employees perform electrical lockout tagout on including but not limited to; electrical panels.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.157 C01

Other-than-serious 2 instances 52 exposed
Issued
Sep 30, 2022
Abate by
Oct 27, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.157(c)(1):Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  a.) Gasbarre Products, Inc.; on or about 5/5/2022 and at times prior thereto, Bay 2 North side press brake area- One class ABC fire extinguisher was not mounted to the wall and was sitting on top of a welder behind the Cincinnati 600 H press brake.  b.) Gasbarre Products, Inc.; on or about 5/5/2022 and at times prior thereto, Bay 2 North side press brake area- One class ABC fire extinguisher was blocked by a welder and compressed gas cylinder behind the Cincinnati 600 H press brake.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Gasbarre Products, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345940704.