WESTFIELD, WI —
OSHA Inspection: BRAKEBUSH BROTHERS, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of BRAKEBUSH BROTHERS, INC. in N4993 6TH DRIVE, WESTFIELD, WI 53964 (NAICS 311615). OSHA activity number 346069651.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BRAKEBUSH BROTHERS, INC.
- Site address
- N4993 6TH DRIVE
- City
- WESTFIELD
- State
- WI
- ZIP
- 53964
- Mailing
- N4993 6TH DRIVE, WESTFIELD, WI 53964
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311615
- Employees
- 1000
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.28 B01 I
- Issued
- Dec 21, 2022
- Abate by
- Jan 23, 2023
- Penalty
- Initial $7,044 · Current $7,044
General-duty citation text
29 CFR 1910.28(b)(1)(i):(1) Unprotected sides and edges. (i) Except as provided elsewhere in this section, the employer must ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the following: (A) Guardrail systems; (B) Safety net systems; or (C) Personal fall protection systems, such as personal fall arrest, travel restraint, or positioning systems: On or about August 10, 2022, at the facility located at N4993 6th Drive, Westfield, Wisconsin, the Spiral Freezer #2 roof platform, near the stairway access, had one unprotected edge 62 inches above the lower roof surface and a second unprotected edge 53 inches above the lower roof surface. The employer had not installed guardrails, safety net system(s) or required personal fall protection system usage to protect employees from the 53 inch and greater fall distances.
Recent events (2)
- — I (S) $7044
- — Z (S) $7044
1910.28 B11 I
- Issued
- Dec 21, 2022
- Abate by
- Jan 23, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.28(b)(11)(i):(i) Each employee exposed to an unprotected side or edge of a stairway landing that is 4 feet (1.2 m) or more above a lower level is protected by a guardrail or stair rail system: On or about August 10, 2022, at the facility located at N4993 6th Drive, Westfield, Wisconsin, the stairway to the Spiral Freezer #2 Roof Platform did not have mid-rails installed on either open side. The stairway landing was 62 inches above the lower roof surface.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.29 B13
- Issued
- Dec 21, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.29(b)(13): When guardrail systems are used around holes that serve as points of access (such as ladderways), the guardrail system opening: (i) Has a self-closing gate that slides or swings away from the hole, and is equipped with a top rail and midrail or equivalent intermediate member that meets the requirements in paragraph (b) of this section; or (ii) is offset to prevent an employee from walking or falling into the hole: a) On or about July 20, 2022, at the facility located at N4993 6th Drive, Westfield, Wisconsin, the ladder access point for the BAC Evaporator Condenser Serial Number U174667302-02-01 work platform did not have a swing gate and was not offset. b) On or about July 20, 2022, at the facility located at N4993 6th Drive, Westfield, Wisconsin, the ladder access point for the BAC Evaporator Condenser Serial Number U174667302-02-02 work platform did not have a swing gate and was not offset.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.119 D03 I
- Issued
- Dec 21, 2022
- Abate by
- Mar 31, 2023
- Penalty
- Initial $8,806 · Current $0 Reduced
General-duty citation text
29 CFR 1910.119(d)(3)(i): 29 CFR 1910.119(d)(3)(i): Process safety information pertaining to the equipment in the process involving highly hazardous chemicals shall include the elements specified in 29 CFR 1910.119(d)(3)(i)(A) through (H): (B) Piping and instrument diagrams (P&ID's) b. On or about July 11, 2022, at the facility located at N4993 6th Drive, Westfield, Wisconsin, the provided safety system information was incomplete and did not include safety system information including, but not limited to: remote Ammonia Refrigeration System/Component E-stops, remote computer control for Ammonia Refrigeration System, fire suppression systems, and Ammonia Refrigeration System component safety-related interlocks.
Recent events (2)
- — I (O) $0
- — Z (S) $8806
1910.119 D03 II
- Issued
- Dec 21, 2022
- Penalty
- Initial $8,806 · Current $8,806
General-duty citation text
29 CFR 1910.119(d)(3)(ii): The employer shall document that equipment complies with recognized and generally accepted good engineering practices: a) On or about July 11, 2022, at the facility located at N4993 6th Drive, West Field, Wisconsin, the employer had not documented the ventilation systems in Engine Rooms 5A and 5B exceeded the ASHRAE 15 and/or IIAR 2 Normal Intermittent Ventilation, Continuously Operating Ventilation and Emergency Ventilation requirements. b) On or about July 11, 2022, at the facility located at N4993 6th Drive, West Field, Wisconsin, the Line #2 Process Area, the HTRL, HTRS and DC ammonia pipelines for Evaporator #17000115 were not labeled. c) On or about July 11, 2022, at the facility located at N4993 6th Drive, West Field, Wisconsin, in the Line #2 Packaging Area, the HTRL, HTRS and DC ammonia pipelines for the Evaporator #17000118 were not labeled. d) On or about July 11, 2022, at the facility located at N4993 6th Drive, West Field, Wisconsin, in the Line #4 Processing Area, the HTRL, HTRS and DC ammonia pipelines for each of the two Evaporators were not labeled. e) On or about July 11, 2022, at the facility located at N4993 6th Drive, West Field, Wisconsin, the Line #9 Marinade Area, the UHRL, UHRS, DC and HG ammonia pipelines for each of the three Evaporators were not labeled. f) On or about July 20, 2022, at the facility located at N4993 6th Drive, West Field, Wisconsin, the Engine Room 4 HTRL pipe line for the High Stage Vessel was not labeled.
Recent events (2)
- — I (S) $8806
- — Z (S) $8806
1910.119 E03 V
- Issued
- Dec 21, 2022
- Abate by
- Jan 23, 2023
- Penalty
- Initial $8,806 · Current $0 Reduced
General-duty citation text
29 CFR 1910.119(e)(3)(v): The process hazard analysis shall address: (v) Facility siting: On or about July 11, 2022, at the facility located at N4993 6th Drive, Westfield, Wisconsin, the last conducted Process Hazard Analysis, performed on October 5, 2020, did not include specific What-If /Checklist Worksheet questions covering all of the facility siting issues examples listed in the Scope section of the Process Hazard Analysis report. The Process Hazard Analysis questions only appeared to address the facility siting issues related to powered equipment contacting components of the ammonia refrigeration systems and did not address the other listed facility sitting issue examples included in the Scope section.
Recent events (2)
- — I (S) $0
- — Z (S) $8806
1910.119 J04 IV
- Issued
- Dec 21, 2022
- Penalty
- Initial $8,806 · Current $8,806
General-duty citation text
29 CFR 1910.119(j)(4)(iv): The employer shall document each inspection and test that has been performed on process equipment. The documentation shall identify the date of the inspection or test, the name of the person who performed the inspection or test, the serial number or other identifier of the equipment on which the inspection or test was performed, a description of the inspection or test performed, and the results of the inspection or test: On or about July 11, 2022, at the facility located at N4993 6th Drive, Westfield, Wisconsin, the inspection of the significant damage to the insulation protecting a section of the Spiral Freezer #2 Hot Gas ammonia pipeline, which was located outdoors and on the roof, was not documented. The insulation damage included insulation metal jacket tears and seam separations.
Recent events (2)
- — I (S) $8806
- — Z (S) $8806
More inspections at Brakebush Brothers, INC.
View Brakebush Brothers, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 311615)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346069651.