OSHA Inspection: BRAKEBUSH BROTHERS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of BRAKEBUSH BROTHERS, INC. in N4993 6TH DRIVE, WESTFIELD, WI 53964 (NAICS 311615). OSHA activity number 346421258.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Brakebush Brothers, INC. — free Get an email when a new federal OSHA severe-injury report for Brakebush Brothers, INC. is published. One employer, no account, unsubscribe in one click.
Site address
N4993 6TH DRIVE
City
WESTFIELD
State
WI
ZIP
53964
Mailing
N4993 6TH DRIVE, WESTFIELD, WI 53964
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311615
Employees
1000
Ownership type
A

7 citations on file for this inspection.

1910.146 D06

Deleted Serious Gravity 5 1 instance 25 exposed
Issued
Jun 30, 2023
Abate by
Jul 31, 2023
Penalty
Initial $9,488 · Current $0 Reduced
29 CFR  1910.146(d)(6): Provide at least one attendant outside the permit space into which entry is authorized for the duration of entry operations;  NOTE: Attendants may be assigned to monitor more than one permit space provided the duties described in paragraph (i) of this section can be effectively performed for each permit space that is monitored. Likewise, attendants may be stationed at any location outside the permit space to be monitored as long as the duties described in paragraph (i) of this section can be effectively performed for each permit space that is monitored.   On or about January 4, 2023, at the facility located at N4993 6th Drive, Westfield, WI, the employer was not utilizing an attendant while an employee was working in a permit required confined space. The employee was working in the L1 Nitrogen Freezer which was designated as a permit required confined space. The employee was utilizing the alternative procedures for entry into a permit required confined space with atmospheric hazards only per 29 CFR 1910.146(c)(5). The L1 Nitrogen Freezer has atmospheric and mechanical hazards which does not meet the requirement for utilization of the alternative procedures for entry into a permit required confined space with atmospheric hazards only per 29 CFR 1910.146(c)(5).
Recent events (3)
  • — F (S) $0
  • — C (S) $9488
  • — Z (S) $9488

1910.146 E01

Deleted Serious Gravity 5 1 instance 25 exposed
Issued
Jun 30, 2023
Abate by
Jul 31, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.146(e)(1): Before entry is authorized, the employer shall document the completion of measures required by paragraph (d)(3) of this section by preparing an entry permit:  On or about January 4, 2023, at the facility located at N4993 6th Drive, Westfield, WI, the required information for a permit required confined space entry permit was not documented on the Confined Space Entry - L1 Freezer Reclassification Documentation for entry into the L1 Nitrogen Freezer. An employee was working in the L1 Nitrogen Freezer which was designated as a permit required confined space. The employee was utilizing the alternative procedures for entry into a permit required confined space with atmospheric hazards only per 29 CFR 1910.146(c)(5). The L1 Nitrogen Freezer has atmospheric and mechanical hazards which does not meet the requirement for utilization of the alternative procedures for entry into a permit required confined space with atmospheric hazards only per 29 CFR 1910.146(c)(5).   The missing information from the Confined Space Entry - L1 Freezer Reclassification Documentation includes, but is not limited to, the following: a) The purpose of the entry. b) The authorized duration of the entry. c) The name of the employee currently serving as the attendant. d) The name of the employee currently  serving as the entry supervisor. e) The hazards of the permit space to be entered. f) The measures used to isolate the permit space and to eliminate or control permit space hazards before entry. g) The acceptable entry conditions. h) The rescue and emergency services that can be summoned and the means for summoning those services. i) The communication procedures used by authorized entrants and attendants to maintain contact during the entry. j) The equipment, such as personal protective equipment, testing equipment, communications equipment, alarm systems, and rescue equipment to be provided for compliance with this section.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.146 C07 III

Deleted Serious Gravity 5 1 instance 25 exposed
Issued
Jun 30, 2023
Abate by
Jul 31, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.146(c)(7)(iii): The employer shall document the basis for determining that all hazards in a permit space have been eliminated, through a certification that contains the date, the location of the space, and the signature of the person making the determination. The certification shall be made available to each employee entering the space or to that employee's authorized representative.  On or about January 4, 2023, at the facility located at N4993 6th Drive, Westfield, WI, the employee entering the Ammonia Spiral Freezers were not documenting the mechanical hazards in the Ammonia Spiral Freezers had been locked out before entry.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.147 C04 I

Deleted Serious Gravity 5 1 instance 15 exposed
Issued
Jun 30, 2023
Abate by
Jul 31, 2023
Penalty
Initial $9,488 · Current $0 Reduced
29 CFR  1910.147(c)(4)(i):Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section (Note: Exception: The employer need not document the required procedure for a particular machine or equipment, when all of the following elements exist: (1) The machine or equipment has no potential for stored or residual energy or reaccumulation of stored energy after shut down which could endanger employees; (2) the machine or equipment has a single energy source which can be readily identified and isolated; (3) the isolation and locking out of that energy source will completely deenergize and deactivate the machine or equipment; (4) the machine or equipment is isolated from that energy source and locked out during servicing or maintenance; (5) a single lockout device will achieve a locker-out condition; (6) the lockout device is under the exclusive control of the authorized employee performing the servicing or maintenance; (7) the servicing or maintenance does not create hazards for other employees; and (8) the employer, in utilizing this exception, has had no accidents involving the unexpected activation or reenergization of the machine or equipment during servicing or maintenance.):  On or about May 5, 2023, at the facility located at N4993 6th Drive, Westfield, WI, the employer had not developed, documented or utilized a lockout procedure for employees entering Flow-Through Pallet Racking lanes to unjam pallets in Freezers 1 and 2.
Recent events (3)
  • — F (S) $0
  • — C (S) $9488
  • — Z (S) $9488

1910.147 C07 I

Other-than-serious Gravity 5 1 instance 12 exposed
Issued
Jun 30, 2023
Abate by
Jul 31, 2023
Penalty
Initial $0 · Current $0
1910.147(c)(7)(i)  The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. The training shall include the following: 29 CFR  1910.147(d)(3): Machine or equipment isolation. All energy isolating devices that are needed to control the energy to the machine or equipment shall be physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):   On or about January 4, 2023, at the facility located at N4993 6th Drive, Westfield, WI, the employee cleaning the Line 4 Marination Area Slicer Infeed Auger Conveyor had not been provided training to ensure the employee understood the purpose and function of, and the knowledge and skills to safely apply, use, and remove, energy controls for the Line 4 Marination Area Slicer Infeed Auger Conveyor.
Recent events (3)
  • — F (O) $0
  • — C (S) $0
  • — Z (S) $0

1910.147 D04 I

Deleted Serious Gravity 5 1 instance 12 exposed
Issued
Jun 30, 2023
Abate by
Jul 31, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.147(d)(4)(i): Lockout or tagout devices shall be affixed to each energy isolating device by authorized employees:  On or about January 4, 2023, at the facility located at N4993 6th Drive, Westfield, WI, the employee cleaning the Line 4 Marination Area, Slicer Infeed Auger Conveyor had not locked out the energy sources for the piece of equipment.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 3 instances 40 exposed
Issued
Jun 30, 2023
Abate by
Jul 31, 2023
Penalty
Initial $9,488 · Current $9,488
29 CFR  1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices, electronic safety devices, etc.:  a) On or about January 5, 2023, at the facility located at N4993 6th Drive, Westfield, WI, the Line 1 Process Area yellow transfer conveyor ingoing nip point created at the tail pulley area was not guarded. The yellow transfer conveyor was located after the initial material breakup auger in the process line.  b) On or about January 5, 2023, at the facility located at N4993 6th Drive, Westfield, WI, the Line 6 Marq Case Sealing System Box Labeler green output conveyor belt tail pulley ingoing nip point was not guarded.  c) On or about January 5, 2023, at the facility located at N4993 6th Drive, Westfield, WI, the Line 9 Marq Tuff Case Sealer (Model  HPV-FB-102-T-T(RH)DL Serial Number Q17015) Lanes 1, 2, and 3 Output Conveyor tail pulley ingoing nip points were not guarded.  d) On or about June 13, 2023, at the facility located at N4993 6th Drive, West Field, the ingoing nip points created by the two sets rollers and the rotating barrel of the Line #1 FPEC Marinator (Model Number VT-85 Serial number 8777), C location, were not guarded.
Recent events (3)
  • — F (S) $9488
  • — C (S) $9488
  • — Z (S) $9488