APPLETON, WI —
OSHA Inspection: DANIEL'S ROOFING & FRAMING, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DANIEL'S ROOFING & FRAMING, LLC in 501 E APPLE CREEK RD, APPLETON, WI 54913 (NAICS 238160). OSHA activity number 346098528.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DANIEL'S ROOFING & FRAMING, LLC
- Site address
- 501 E APPLE CREEK RD
- City
- APPLETON
- State
- WI
- ZIP
- 54913
- Mailing
- 3803 SEWARD AVE, ROCKFORD, IL 61108
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 8
- Ownership type
- A
Citations
5 citations on file for this inspection.
1903.19 C01
- Issued
- Nov 10, 2022
- Abate by
- Dec 12, 2022
- Penalty
- Initial $349 · Current $349
General-duty citation text
29 CFR 1903.19(c)(1):Within 10 calendar days after the abatement date, the employer must certify to OSHA (the Agency) that each cited violation has been abated, except as provided in paragraph (c)(2) of this section. The employer failed to provide abatement certification for the citation issued on August 4, 2022.
Recent events (1)
- — Z (O) $349
1903.19 D01
- Issued
- Nov 10, 2022
- Abate by
- Dec 12, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1903.19(d)(1):The employer must submit to the Agency, along with the information on abatement certification required by paragraph (c)(3) of this section, documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required. The employer failed to provide abatement certification for the citation issued on August 4, 2022.
Recent events (1)
- — Z (O) $0
1926.100 A
- Issued
- Aug 4, 2022
- Abate by
- Sep 1, 2022
- Penalty
- Initial $2,486 · Current $2,486
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets. On or about July 22, 2022, at a jobsite located at 501 East Apple Creek Road Appleton, Wisconsin, two employees of Daniel's Roofing & Framing LLC were completing clean up operations of fallen debris from a residential roofing project without protective helmets while being exposed to potential injuries from falling objects.
Recent events (1)
- — Z (S) $2486
1926.501 B13
- Issued
- Aug 4, 2022
- Abate by
- Sep 1, 2022
- Penalty
- Initial $4,351 · Current $4,351
General-duty citation text
29 CFR 1926.501(b)(13):"Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems. On or about July 22, 2022, at a jobsite located at 501 E Apple Creek Road Appleton, Wisconsin, the employer did not ensure that employees removing shingles on an existing roof greater than 10 feet above lower levels were protected from fall hazards by a conventional form of fall protection.
Recent events (1)
- — Z (S) $4351
1926.1053 B01
- Issued
- Aug 4, 2022
- Penalty
- Initial $3,108 · Current $3,108
General-duty citation text
29 CFR 1926.1053(b)(1):When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. On or about July 22, 2022, at a jobsite located at 501 East Apple Creek Road Appleton, Wisconsin, the 20 foot Werner aluminum extension ladder used to access the roof on the northern side of the residence did not extend at least three feet past the upper landing surface exposing employees to slips and fall hazards.
Recent events (1)
- — Z (S) $3108
More inspections at Daniel'S Roofing & Framing, LLC
View Daniel'S Roofing & Framing, LLC's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346098528.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.