TAMUNING, GU —
OSHA Inspection: PEPSI GUAM BOTTLING
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PEPSI GUAM BOTTLING in 210 ROJAS STREET HARMON INDUSTRIAL PARK, TAMUNING, GU 96913 (NAICS 312111). OSHA activity number 346276066.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PEPSI GUAM BOTTLING
- Site address
- 210 ROJAS STREET HARMON INDUSTRIAL PARK
- City
- TAMUNING
- State
- GU
- ZIP
- 96913
- Mailing
- 210 ROJAS STREET HARMON INDUSTRIAL PARK, TAMUNING, GU 96913
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 312111
- Employees
- 109
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.134 F02
- Issued
- Feb 22, 2023
- Abate by
- Mar 27, 2023
- Penalty
- Initial $6,026 · Current $4,821 Reduced
General-duty citation text
29 CFR 1910.134(f)(2): Employee(s) using a tight-fitting facepiece respirator were not annually fit tested: 5 Gallon room: At least one employee required to wear a half face respirator was not annually fit tested. Employees were exposed to respiratory hazards.
Recent events (3)
- — F (S) $4820.8
- — C (S) $6026
- — Z (S) $6026
1910.147 C04 II C
- Issued
- Feb 22, 2023
- Abate by
- Mar 27, 2023
- Penalty
- Initial $8,036 · Current $6,429 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(C): The energy control procedure did not clearly and specifically outline the steps for placement, removal and transfer of lockout devices or tagout devices and the responsibility for them. a. Production Floor: The labeler was serviced weekly without procedural steps for shutting down, isolating, blocking, and securing, the hazardous energy. Employees were exposed to caught-in, struck by, and crushing hazards. b. Production Floor: The blow mold was serviced weekly without procedural steps for shutting down, isolating, blocking, and securing, the hazardous energy. Employees were exposed to caught-in, struck by, and crushing hazards. c. Production Floor: The palletizer was serviced weekly without procedural steps for shutting down, isolating, blocking, and securing, the hazardous energy. Employees were exposed to caught-in, struck by, and crushing hazards. d. Production Floor: The packer was serviced weekly without procedural steps for shutting down, isolating, blocking, and securing, the hazardous energy. Employees were exposed to caught-in, struck by, and crushing hazards.
Recent events (3)
- — F (S) $6428.8
- — C (S) $8036
- — Z (S) $8036
1910.147 C04 II D
- Issued
- Feb 22, 2023
- Abate by
- Mar 27, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control a. Production Floor: The labeler was serviced weekly without specific requirements for testing the effectiveness of tagout devices. Employees were exposed to caught-in, struck by, and crushing hazards. b. Production Floor: The blow mold was serviced weekly without specific requirements for testing the effectiveness of tagout devices. Employees were exposed to caught-in, struck by, and crushing hazards. c. Production Floor: The palletizer was serviced weekly without specific requirements testing the effectiveness of tagout devices. Employees were exposed to caught-in, struck by, and crushing hazards. d. Production Floor: The packer was serviced weekly without specific requirements for testing the effectiveness of tagout devices. Employees were exposed to caught-in, struck by, and crushing hazards.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Feb 22, 2023
- Abate by
- Mar 13, 2023
- Penalty
- Initial $6,026 · Current $4,821 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: Maintenance Shop: AJET JDP-15MF drill press stock number 354166 was operated without a chuck guard. Employees were exposed to rotating part hazards.
Recent events (3)
- — F (S) $4820.8
- — C (S) $6026
- — Z (S) $6026
1910.219 F03
- Issued
- Feb 22, 2023
- Abate by
- Mar 13, 2023
- Penalty
- Initial $8,036 · Current $6,429 Reduced
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven (7) feet or less above floors, or platforms were not enclosed: Production Floor: The packer was operated with the proximity switch disabled allowing employees to access inside the sliding guard doors with unprotected chains and sprockets to fix tray alignment. Employees were exposed to caught in hazards.
Recent events (3)
- — F (S) $6428.8
- — C (S) $8036
- — Z (S) $8036
1910.305 B01 II
- Issued
- Feb 22, 2023
- Penalty
- Initial $6,026 · Current $4,821 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a. Production Floor: A circuit breaker/cover was missing from CKT 3 in Main electrical panel G. Employees were exposed to electrical hazards. b. Production Floor: A circuit breaker/cover was missing from slot 4 and 6 in electrical panel G. Employees were exposed to electrical hazards. c. Production floor: A circuit breaker/cover was missing from the right column third slot from the top in the General Electric electrical panel to the right of main panel G. Employees were exposed to electrical hazards d. Production floor: The hot water heater junction box was missing two knockouts. Employees were exposed to electrical hazards
Recent events (3)
- — F (S) $4820.8
- — C (S) $6026
- — Z (S) $6026
1910.305 B02 I
- Issued
- Feb 22, 2023
- Abate by
- Mar 13, 2023
- Penalty
- Initial $6,026 · Current $4,821 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: a. Beside the roll up door: The junction box below the controls for the roll-up door had no cover and exposed conductors. Employees were exposed to electrical hazards. b. Ice plant: A junction box had no cover and exposed conductors. Employees were exposed to electrical hazards.
Recent events (3)
- — F (S) $4820.8
- — C (S) $6026
- — Z (S) $6026
1910.212 A01
- Issued
- Feb 22, 2023
- Abate by
- Mar 20, 2023
- Penalty
- Initial $120,539 · Current $84,377 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: Production Floor: The Accraply 4500 Labeler was operated with its safety proximity switch disabled and the guard doors open. Employees were exposed to rotating parts, in-going nip point, and burn hazards.
Recent events (3)
- — F (W) $84377.3
- — C (W) $120539
- — Z (W) $120539
5(a)(1)
- Issued
- Feb 22, 2023
- Penalty
- Initial $20,092 · Current $16,074 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck-by and/or crushed-by hazards. Warehouse: A racking system in aisle f-28 was used with a damaged column and cross brace to store pallets of bottled water. Employees were exposed to struck-by and crushed-by hazards. Pepsi Guam Bottling was previously cited for a violation of this occupational safety and health standard OSH ACT of 1970 Section (5)(a)(1), for damaged storage racks which was contained in OSHA inspection number 1538513, citation number 1, item number 1 and was affirmed as a final order on 10/18/2021, with respect to a workplace located at 210 Rojas Street Harmon Industrial Park Tamuning, GU 96913.
Recent events (3)
- — F (R) $16073.6
- — C (R) $20092
- — Z (R) $20092
More inspections at Pepsi Guam Bottling
View Pepsi Guam Bottling's full OSHA safety record →
More inspections in this industry (NAICS 312111)
More inspections in GU
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346276066.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.