Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: LANGSTON BAG OF PEORIA, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of LANGSTON BAG OF PEORIA, LLC in 1114 SW ADAMS, PEORIA, IL 61604 (NAICS 326111). OSHA activity number 346743743.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Langston BAG of Peoria, LLC — free Get an email when a new federal OSHA severe-injury report for Langston BAG of Peoria, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1114 SW ADAMS
City
PEORIA
State
IL
ZIP
61604
Mailing
1114 SW ADAMS, PEORIA, IL 61604
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326111
Employees
67
Ownership type
A

4 citations on file for this inspection.

1910.28 B11 II

Other-than-serious Gravity 1 1 instance 1 exposed
Issued
Oct 30, 2023
Abate by
Nov 30, 2023
Penalty
Initial $3,984 · Current $0 Reduced
29 CFR 1910.28(b)(11)(ii): The employer did not ensure that each flight of stairs having at least 3 treads and at least 4 risers is equipped with stair rail systems and handrails as described in 29 CFR 1910.28 Table D-2-Stairway Handrail Requirements:  On or about June 13, 2023, employees who used the dock door stairway next to Dock 1 were exposed to fall hazards because the employer did not ensure each open side of the stairway was equipped with a handrail.
Recent events (2)
  • — I (O) $0
  • — Z (S) $3984

1910.212 A01

Serious Gravity 5 3 instances 2 exposed
Issued
Oct 30, 2023
Abate by
Nov 30, 2023
Penalty
Initial $6,641 · Current $4,500 Reduced
29 CFR  1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:   On or about June 13, 2023, employees were exposed to amputation, caught-in, and entanglement hazards because the employer did not ensure:  a. Tuber #3 roller adjustment gates were guarded to prevent ingoing nips and rotating parts.  Two of the three gates could not be latched, and the middle gate latched but was easily defeated without special knowledge or tools.   b. Tuber #3 was guarded near point of operation to prevent ingoing nips, entanglement, and amputation hazards.  Components such as belts, rollers, and perforators were used to cut, fold, and seal bags.
Recent events (2)
  • — I (S) $4500
  • — Z (S) $6641

1910.303 G01 I

Serious Gravity 5 4 instances 7 exposed
Issued
Oct 30, 2023
Abate by
Nov 30, 2023
Penalty
Initial $6,641 · Current $4,500 Reduced
29 CFR  1910.303(g)(1)(i): The dimension of the working space in the direction of access to live parts operating at 600 volts or less and likely to require examination, adjustment, servicing, or maintenance while alive was less than indicated in Table S1:   On or about June 13, 2023, employees were exposed to electrical and fire-related hazards because the employer did not ensure at least three feet of space was maintained around electrical panels and disconnects:  a. Maintenance Area South wall - one 240V electrical panel and 6 disconnects up to 480V were blocked by a wire bin and a metal drum that were being stored in front of the equipment.  b. Maintenance Area East wall - one 480V electrical panel blocked by Cybertech control unit.  c. C Building, back wall near Tuber #4 - one 208V electrical panel blocked by stored adhesive gaylord.  d. North wall next to Faustel printer - one electrical panel blocked by stored equipment.
Recent events (2)
  • — I (S) $4500
  • — Z (S) $6641

1910.303 G01 II

Deleted Serious Gravity 5 4 instances 7 exposed
Issued
Oct 30, 2023
Abate by
Nov 30, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:   On or about June 13, 2023, employees were exposed to electrical and fire-related hazards because the employer did not ensure electrical equipment was not blocked by stored equipment:  a. Maintenance Area South wall - one 240V electrical panel and 6 disconnects up to 480V were blocked by a wire bin and a metal drum that were being stored in front of the equipment.  b. Maintenance Area East wall - one 480V electrical panel blocked by Cybertech control unit.  c. C Building, back wall near Tuber #4 - one 208V electrical panel blocked by stored adhesive gaylord.  d. North wall next to Faustel printer - one electrical panel blocked by stored equipment.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Langston BAG of Peoria, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346743743.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.