PEORIA, IL —
OSHA Inspection: LANGSTON BAG OF PEORIA, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of LANGSTON BAG OF PEORIA, LLC in 1114 SW ADAMS, PEORIA, IL 61604 (NAICS 322220). OSHA activity number 347472763.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LANGSTON BAG OF PEORIA, LLC
- Site address
- 1114 SW ADAMS
- City
- PEORIA
- State
- IL
- ZIP
- 61604
- Mailing
- 1114 SW ADAMS, PEORIA, IL 61604
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 322220
- Employees
- 67
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C04 II
- Issued
- Aug 6, 2024
- Abate by
- Sep 5, 2024
- Penalty
- Initial $11,292 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): On or about February 27, 2024, an employee was exposed to hazardous energy while troubleshooting an air leak on the Pinch Bottomer and the employer's machine specific procedures did not include hazardous energy control procedures for the trouble shooting operation.
Recent events (2)
- — I (S) $0
- — Z (S) $11292
1910.147 C07 III B
- Issued
- Aug 6, 2024
- Abate by
- Sep 5, 2024
- Penalty
- Initial $11,292 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(iii)(B): Additional retraining was not provided whenever a periodic inspection under 29 CFR 1910.147(c)(6) revealed that there were deviations from or inadequacies in the employee's knowledge or use of the energy control procedures: On February 27, 2024, an employee was exposed to amputation hazards while troubleshooting an air leak on Pinch Bottomer Feeder without following lockout procedures and the employer did not ensure that retraining was provided due to deviations of the employee's use of energy control procedures.
Recent events (2)
- — I (O) $0
- — Z (S) $11292
More inspections at Langston BAG of Peoria, LLC
View Langston BAG of Peoria, LLC's full OSHA safety record →
More inspections in this industry (NAICS 322220)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347472763.