Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: W.G. STANG, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of W.G. STANG, LLC in 11 PLEASANT ST., LEBANON, OH 45036 (NAICS 237110). OSHA activity number 346832371.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch W.G. Stang, LLC — free Get an email when a new federal OSHA severe-injury report for W.G. Stang, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
W.G. STANG, LLC
Site address
11 PLEASANT ST.
City
LEBANON
State
OH
ZIP
45036
Mailing
2403 JACKSONBURG ROAD, HAMILTON, OH 45011
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
17
Ownership type
A

2 citations on file for this inspection.

1926.651 C02

Serious Gravity 10 1 instance 2 exposed
Issued
Aug 25, 2023
Penalty
Initial $6,875 · Current $4,813 Reduced
29 CFR  1926.651(c)(2):Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.  a.) On July 14, 2023, the employer failed to ensure that a stairway, ladder, ramp, or other safe means of egress was provided for employees working in a trench excavation that was between 6'-6" and 7'-2" in depth. As a result, employees working in the trench were exposed to the hazards of delayed egress in the event of an accident or emergency.
Recent events (2)
  • — I (S) $4812.5
  • — Z (S) $6875

1926.652 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Aug 25, 2023
Penalty
Initial $6,875 · Current $4,813 Reduced
29 CFR  1926.652(a)(1):Each employee in an excavation shall be protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section except when: -Excavations are made entirely in stable rock; or -Excavations are less than 5 feet (1.52m) in depth and examination of the ground by a competent person provides no indication of a potential cave-in.  a.) On July 14, 2023, the employer failed to ensure that employees were protected from cave-in hazards by an adequate protective system in that, employees were found working in a trench without cave-in protection. The trench measured up to 7'-2" deep, with straight vertical sidewalls.
Recent events (2)
  • — I (S) $4812.5
  • — Z (S) $6875

View W.G. Stang, LLC's full OSHA safety record →