Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DONCASTERS PRECISION CASTINGS - NEW ENGLAND

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of DONCASTERS PRECISION CASTINGS - NEW ENGLAND in 835 POQUONNOCK ROAD, GROTON, CT 06340 (NAICS 331512). OSHA activity number 347041956.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Doncasters Precision Castings - NEW England — free Get an email when a new federal OSHA severe-injury report for Doncasters Precision Castings - NEW England is published. One employer, no account, unsubscribe in one click.
Site address
835 POQUONNOCK ROAD
City
GROTON
State
CT
ZIP
06340
Mailing
P.O. BOX 1146, GROTON, CT 06340
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331512
Employees
235
Ownership type
A

2 citations on file for this inspection.

1910.1000 D02 I

Serious Gravity 10 3 instances 7 exposed
Issued
Apr 18, 2024
Abate by
Jul 8, 2024
Penalty
Initial $13,711 · Current $6,856 Reduced
29 CFR 1910.1000(d)(2)(i): Employees were exposed to a nickel, cobalt, and chromium metal mixture in excess of the cumulative exposure limit:   Rotofile Area: On or about October 26, 2024, and some time thereafter, employees were exposed in excess of the cumulative exposure limit to a nickel, cobalt, and chromium metal mixture in the following instances:  a) The violation was observed when an employee was exposed in excess of the cumulative exposure limit during rotofile operations where die grinders and orbital sanders were used to pre-finish aerospace metal alloy castings that contained a mixture of nickel, cobalt, and chromium metals. An employee was exposed to nickel metal at concentrations of 0.695 milligrams per cubic meter of air (mg/m3), cobalt metal at concentrations of 0.071 mg/m3, and chromium metal at 0.236 mg/m3 as an eight-hour time-weighted average (8-hr TWA) during a sample period of 297 minutes, using zero exposure for the unsampled portion of the 8-hour shift. With an equivalent exposure for the mixture of 1.64 and a mixture control limit of 1.07, it confirmed that an overexposure had occurred within 95% confidence limits.  b) The violation was observed when an employee was exposed in excess of the cumulative exposure limit during gate grinding operations where carbide grinders and orbital sanders were used to pre-finish aerospace metal alloy parts that contained a mixture of nickel, cobalt, and chromium metals. An employee was exposed to nickel metal at concentrations of 0.477 milligrams per cubic meter of air (mg/m3), cobalt metal at concentrations of 0.055 mg/m3, and chromium metal at 0.160 mg/m3 as an eight-hour time-weighted average (8-hr TWA) during a sample period of 375 minutes, using zero exposure for the unsampled portion of the 8-hour shift. With an equivalent exposure for the mixture of 1.19 and a mixture control limit of 1.07, it confirmed that an overexposure had occurred within 95% confidence limits.
Recent events (4)
  • — P (S) $6855.5
  • — I (S) $6855.5
  • — P (S) $6855.5

1910.1000 E

Serious Gravity 10 1 instance 7 exposed
Issued
Apr 18, 2024
Abate by
Jul 8, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.1000(e): Feasible administrative or engineering controls were not determined and implemented to achieve compliance with the limits prescribed in 29 CFR 1910.1000(a) through (d): Rotofile Area:  The employer did not ensure that feasible administrative or engineering controls were determined and implemented to prevent or reduce harmful exposures to a mixture of metal alloys including nickel, cobalt, and chromium metals during rotofiling and gate grinding operations. Employees were exposed in excess of the permissible exposure limits prescribed in 29 CFR 1910.1000(a) through (d)
Recent events (4)
  • — P (S) $0
  • — I (S) $0
  • — P (S) $0

View Doncasters Precision Castings - NEW England's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347041956.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.