Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SOBOBA CASINO RESORT

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SOBOBA CASINO RESORT in 22777 SOBOBA ROAD, SAN JACINTO, CA 92583 (NAICS 721120). OSHA activity number 347083875.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Soboba Casino Resort — free Get an email when a new federal OSHA severe-injury report for Soboba Casino Resort is published. One employer, no account, unsubscribe in one click.
Site address
22777 SOBOBA ROAD
City
SAN JACINTO
State
CA
ZIP
92583
Mailing
PO BOX 817, SAN JACINTO, CA 92581
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
721120
Employees
500
Ownership type
A

9 citations on file for this inspection.

1910.213 D01

Serious Gravity 1 1 instance 2 exposed
Issued
Dec 13, 2023
Abate by
Jan 18, 2024
Penalty
Initial $6,696 · Current $3,683 Reduced
29 CFR  1910.213(d)(1): Circular handfed crosscut table saw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut:  Carpenter Shop, Building 22333: On and/or before November 2, 2023, a Delta table saw model #36-L300 was not guarded by an automatically adjusted hood which completely enclosed that portion of the saw above the table and above the material being cut. Employee(s) were possibly exposed to laceration hazard(s).
Recent events (2)
  • — I (S) $3683
  • — Z (S) $6696

1910.213 I01

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 13, 2023
Abate by
Jan 18, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.213(i)(1): Non-working portion(s) of the blade of bandsaw(s) were not enclosed or guarded:  Carpenter Shop, Building 22333: On and/or before November 2, 2023, the non-working portion(s) of the blade for the Jet bandsaw were not enclosed or guarded when employee(s) cut sandpaper. Approximately 2 inches of the blade was exposed. Employee(s) were possibly exposed to laceration/amputation hazard(s).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.242 B

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 13, 2023
Abate by
Jan 18, 2024
Penalty
Initial $8,929 · Current $4,911 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:  Carpenter shop, building 22333: On and/or before November 2, 2023, employee(s) used compressed air to clean off projects. The p.s.i was not reduced to less than 30 p.s.i. This condition potentially exposed employee(s) to cutaneous or subcutaneous laceration(s)/embolism hazard(s).
Recent events (2)
  • — I (S) $4911
  • — Z (S) $8929

1910.303 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 13, 2023
Abate by
Jan 18, 2024
Penalty
Initial $13,394 · Current $7,677 Reduced
29 CFR  1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  Carpenter Shop, building 22333: On and/or before November 2, 2023, multiple machines such as a drum sander, Jet band saw, and a Dayton Belt & disc sander were plugged into a relocatable power tap and extension cord. These machines were not used according to listing and labeling instructions. This condition potentially exposed employee(s) to electrical shock and/or fire hazards.
Recent events (2)
  • — I (S) $7677
  • — Z (S) $13394

1910.305 G01 IV A

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Dec 13, 2023
Abate by
Jan 18, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  Auto-shop, building 22333: On and/or before November 2, 2023, a blue safety clean parts cleaner was plugged into a yellow flexible cord. The yellow flexible cord was used as a substitute for the fixed wiring of a structure. This condition potentially exposed employee(s) to electrical shock and/or fire hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.101 B

Repeat Gravity 1 2 instances 6 exposed
Issued
Dec 13, 2023
Penalty
Initial $33,480 · Current $18,414 Reduced
29 CFR  1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6:  Section 3.3.1 of the CGA Pamphlet P-1-1965 refers to storing cylinders in accordance with CGA and NFPA standards. The CGA Pamphlet P-1-1991 Section 3.7.4.1 states that "All compressed gas cylinders in service or in storage shall be secured to prevent from falling."  On and/or before November 2, 2023, two compressed cylinders that held nitrogen and one that held acetylene were upright and unsecured from displacement. In the following locations: b) Plumbers cage of Maintenance warehouse. Employee(s) were potentially exposed to struck-by hazard(s).  Soboba Casino Resort was previously cited for a violation of this Occupational Safety and Health Standard 29 CFR  1910.101(b), which was contained in OSHA inspection number 1384379, citation number 1, item number 2 and was affirmed as a final order on May 16, 2019, with respect to a workplace located at 22777 Soboba Road San Jacinto, CA 92583.
Recent events (2)
  • — I (R) $18414
  • — Z (R) $33480

1910.157 C01

Other-than-serious 1 instance 2 exposed
Issued
Dec 13, 2023
Abate by
Jan 25, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  Carpenter shop, building 22333: On and/or before November 2, 2023, extinguisher(s) were not mounted to the wall. Unmounted fire extinguisher(s) may cause a delayed response and/or inability to locate during an emergency. This condition potentially exposed employee(s) to fire and/or smoke inhalation hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.157 E02

Other-than-serious 1 instance 500 exposed
Issued
Dec 13, 2023
Abate by
Jan 25, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:  Soboba Casino Resort: On and/or before November 2, 2023, Kiddie, Amerex, Ansul, and Badger fire extinguishers were not visually inspected at least monthly. This condition potentially exposed employee(s) to fire hazard(s).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.244 A01 II

Other-than-serious 1 instance 2 exposed
Issued
Dec 13, 2023
Abate by
Jan 25, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.244(a)(1)(ii): Rated load(s) of portable jack(s) were not legibly and permanently marked in a prominent location on the jack(s) by casting, stamping, or other suitable means:  Auto shop: On and or/before November 2, 2023, employee(s) used a brown unlabeled hydraulic portable jack(s) that did not have permanently marked rated loads. Employee(s) were potentially exposed to crush by/ pinch hazard(s).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Soboba Casino Resort's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347083875.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.