OSHA Inspection: AGROPUR INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of AGROPUR INC. in 3805 NORTH FREEDOM ROAD, APPLETON, WI 54913 (NAICS 311513). OSHA activity number 347167561.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Agropur INC. — free Get an email when a new federal OSHA severe-injury report for Agropur INC. is published. One employer, no account, unsubscribe in one click.
Establishment
AGROPUR INC.
Site address
3805 NORTH FREEDOM ROAD
City
APPLETON
State
WI
ZIP
54913
Mailing
3805 NORTH FREEDOM ROAD, APPLETON, WI 54913
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311513
Employees
150
Ownership type
A

6 citations on file for this inspection.

1910.28 B02 I

Serious Gravity 5 1 instance 10 exposed
Issued
May 24, 2024
Abate by
Jun 25, 2024
Penalty
Initial $11,524 · Current $7,500 Reduced
29 CFR  1910.28(b)(2)(i): 29 CFR 1910.28(b)(2)(i): The employer did not ensure that each employee in a hoist area is protected from falling 4 feet (1.2 m) or more to a lower level by one of the systems listed in 29 CFR 1910.28(b)(2)(i)(A)-(C).  On or about December 29, 2023, at the facility located at 3805 North Freedom Road, Appleton, Wisconsin; the employer failed to ensure that when employees were receiving materials at  the mezzanine in Packaging that they were protected from falls into the hoist area opening.
Recent events (2)
  • — I (S) $7500
  • — Z (S) $11524

1910.147 E02 I

Other-than-serious Gravity 5 1 instance 10 exposed
Issued
May 24, 2024
Abate by
Jul 26, 2024
Penalty
Initial $11,524 · Current $7,500 Reduced
29 CFR 1910.147(e)(2)(i):   The work area shall be checked to ensure that all employees have been safely positioned or removed.  On or about February 16, 2024, at the facility located at 3805 North Freedom Road, Appleton, Wisconsin; an employee was exposed to machine hazards associated with moving parts while assisting another employee in sanitation on Molder #3.  The one employee was exposed to hazardous machine movement while assisting, and the other employee was using the controls to move the ram.  The employer did not ensure that employees implemented energy control application steps or equivalent protective measures prior to allowing them to sanitize the equipment.  The machine was not deenergized prior to the employee engaging in servicing/maintenance activity.  As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], lockout/tagout device application [1910.147(d)(4)], dissipation of residual energy [1910(d)(5)(i)], and verification of isolation [1910.147(d)(6)] were not implemented to protect employees from machine hazards.
Recent events (2)
  • — I (O) $7500
  • — Z (S) $11524

1910.151 C

Other-than-serious Gravity 5 1 instance 2 exposed
Issued
May 24, 2024
Abate by
Jul 26, 2024
Penalty
Initial $11,524 · Current $3,500 Reduced
29 CFR 1910.151(c): Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use.  Reference: ANSI Z358.1 Emergency Eyewash and Shower Standard  On or about May 2, 2024, at the facility located at 3805 North Freedom Road, Appleton, Wisconsin; the employer failed to ensure employees exposed to injurious corrosive chemicals in the HTST Room were provided with suitable facilities for quick drenching or flushing of the eyes and body, exposing employee to potential chemical burns during sanitation of equipment using Hydroxysan Plus and Dura Foam No 263.
Recent events (2)
  • — I (O) $3500
  • — Z (S) $11524

1910.303 G01 III

Other-than-serious Gravity 5 1 instance 4 exposed
Issued
May 24, 2024
Abate by
Jun 25, 2024
Penalty
Initial $9,218 · Current $3,500 Reduced
29 CFR 1910.303(g)(1)(iii): At least one entrance of sufficient area shall be provided to give access to the working space about electric equipment.   On or about December 15, 2023, at the facility located at 3805 North Freedom Road, Appleton, Wisconsin; the employer failed to ensure sufficient access to the 1HB circuit breaker panel located in the Shipping and Receiving Area.
Recent events (2)
  • — I (O) $3500
  • — Z (S) $9218

1910.305 B01 I

Other-than-serious Gravity 1 1 instance 4 exposed
Issued
May 24, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter shall be effectively closed.  On or about December 15, 2023, at the facility located at 3805 North Freedom Road, Appleton, Wisconsin; the employer failed to ensure the junction box (1HB-2, 4, 6) opening for the conductors from the S.P.E. Electronica Industriale (Model No.: GREENX48-300, Serial No.: 2930157) battery charger was effectively closed.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.305 G01 IV A

Deleted Serious Gravity 1 1 instance 3 exposed
Issued
May 24, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): 29 CFR 1910.305(g)(1)(iv)(A): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used as a substitute for the fixed wiring of a structure.  On or about December 15, 2023, at the facility located at 3805 North Freedom Road, Appleton, Wisconsin; the employer failed to ensure that flexible cords were not used as a substitute for permanent wiring.  The employer used an extension cord to plug in two chest freezers in the Shipping and Receiving Area.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Agropur INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347167561.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.