Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: A & B REMODELING LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of A & B REMODELING LLC in 46 WATERFORD CIR, MADISON, WI 53711 (NAICS 238160). OSHA activity number 347379877.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch A & B Remodeling LLC — free Get an email when a new federal OSHA severe-injury report for A & B Remodeling LLC is published. One employer, no account, unsubscribe in one click.
Site address
46 WATERFORD CIR
City
MADISON
State
WI
ZIP
53711
Mailing
3159 VIEW RD, MADISON, WI 53711
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238160
Employees
9
Ownership type
A

5 citations on file for this inspection.

1903.19 C01

Other-than-serious 1 instance 1 exposed
Issued
Oct 24, 2024
Abate by
Dec 16, 2024
Penalty
Initial $427 · Current $427
29 CFR  1903.19(c)(1):Within 10 calendar days after the abatement date, the employer must certify to OSHA (the Agency) that each cited violation has been abated, except as provided in paragraph (c)(2) of this section.  a)  The employer failed to submit certification of abatement within 10 calendar days of the abatement date for Citation 1 Item 1.
Recent events (1)
  • — Z (O) $427

1903.19 D01

Other-than-serious 1 instance 1 exposed
Issued
Oct 24, 2024
Abate by
Dec 16, 2024
Penalty
Initial $0 · Current $0
29 CFR  1903.19(d)(1):The employer must submit to the Agency, along with the information on abatement certification required by paragraph (c)(3) of this section, documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required.  a)  The employer failed to submit documentation of abatement within 10 days of the abatement date for Citation 2 Item 1, and Citation 3 Item 1.
Recent events (1)
  • — Z (O) $0

1926.1053 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 3, 2024
Abate by
Sep 17, 2024
Penalty
Initial $3,803 · Current $3,803
29 CFR  1926.1053(b)(1):  Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:  On or about March 28, 2024, a portable extension ladder used for access to an upper roof surface did not extend at least 3 feet (.9m) above the upper roof surface which the ladder was used to gain access to.
Recent events (1)
  • — Z (S) $3803

1926.501 B13

Willful Gravity 10 1 instance 8 exposed
Issued
Sep 3, 2024
Abate by
Sep 17, 2024
Penalty
Initial $35,491 · Current $35,491
29 CFR  1926.501(b)(13):  Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):  On or about March 28, 2024, employees engaged in roofing activities were exposed to fall hazards greater than 19 feet and were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b).
Recent events (1)
  • — Z (W) $35491

1926.503 A01

Repeat Gravity 5 1 instance 1 exposed
Issued
Sep 3, 2024
Abate by
Sep 24, 2024
Penalty
Initial $7,606 · Current $7,606
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:  On or about March 28, 2024, the employer did not ensure that employees exposed to potential fall hazards had been trained to recognize and minimize the fall hazards associated with their work.  A & B Remodeling LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.503(a)(1), which was contained in OSHA inspection number 1523444, citation number 1, item number 3, and was affirmed as a final order on July 22, 2021, with respect to a workplace located at 8100 North Beach Drive, Fox Point, WI 53217.