OSHA Inspection: WILDHORSE RESORT AND CASINO

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WILDHORSE RESORT AND CASINO in 46510 WILDHORSE BLVD, PENDLETON, OR 97801 (NAICS 713210). OSHA activity number 347406712.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Wildhorse Resort and Casino — free Get an email when a new federal OSHA severe-injury report for Wildhorse Resort and Casino is published. One employer, no account, unsubscribe in one click.
Site address
46510 WILDHORSE BLVD
City
PENDLETON
State
OR
ZIP
97801
Mailing
46510 WILDHORSE BLVD, PENDLETON, OR 97801
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
713210
Employees
600
Ownership type
A

9 citations on file for this inspection.

1910.303 G01

Serious Gravity 1 3 instances 30 exposed
Issued
May 23, 2024
Abate by
Jun 20, 2024
Penalty
Initial $5,876 · Current $2,938 Reduced
29 CFR  1910.303(g)(1):Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  (a)  Coffee Shop area, on or about 11 April 2024 and at times thereof: Employees were exposed to electrical fire hazard due to numerous electrical panels blocked by combustible materials, carts, and miscellaneous objects. resulting in burn/ electrocution injuries.  (b)  Facilities building, on or about 11 April 2024 and at times thereof: Employees were exposed to electrical fire hazard due to numerous electrical panels blocked by combustible materials, carts, and miscellaneous objects. resulting in burn/ electrocution injuries.  (c)  Employee break area, on or about 11 April 2024 and at times thereof: Employees were exposed to electrical fire hazard due to numerous electrical panels blocked by combustible materials, carts, and miscellaneous objects. resulting in burn/ electrocution injuries.
Recent events (2)
  • — I (S) $2938
  • — Z (S) $5876

1910.22 A01

Other-than-serious 1 instance 3 exposed
Issued
May 23, 2024
Abate by
Jun 20, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.22(a)(1):All places of employment, passageways, storerooms, service rooms, and walking-working surfaces were not kept in a clean, orderly, and sanitary condition:  (a) Coffee Shop area,  on or about 11 April 2024 and at times thereof:  Employees were exposed to trip fall hazard due to protruding objects (food prep carts, sanitary equipment) in employee work space area. Resulting in potential minor injuries to body extremities.  (b) Hotel facility maintenance area, Employees were exposed to trip fall hazard due to protruding objects (food prep carts, sanitary equipment) in employee work space area. Resulting in minor injuries to body extremities.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.22 C

Other-than-serious 2 instances 6 exposed
Issued
May 23, 2024
Abate by
Jun 20, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.22(c):The employer did not provide, and ensure each employee used, a safe means of access and egress to and from walking-working surfaces:  (a) Coffee Shop area, on or about 12 April 2024 and at times thereof: Employees were exposed to trip fall hazard due to protruding objects (food prep carts, sanitary equipment) in employee workspace area. Resulting in potential minor injuries to body extremities.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.37 A04

Other-than-serious 2 instances 30 exposed
Issued
May 23, 2024
Abate by
Jun 20, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.37(a)(4):Safeguards designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting) were not in proper working order at all times.  (a) Coffee Shop area, on or about 11 April 2024 and at times thereof: Employees were exposed to an exit route path lighting that is not operational. Resulting in potential trip/fall  and burn injuries from trying to exit building during an emergency event.  (b)  H/R Building, on or about 11 April 2024 and at times thereof: Employees were exposed to an exit route path lighting that is not operational. Resulting in trip/fall  and burn injuries from trying to exit building during an emergency event.  (c) Facilities shop area, on or about 11 April 2024 and at times thereof: Employees were exposed to an exit route path lighting that is not operational. Resulting in trip/fall  and burn injuries from trying to exit building during an emergency event.    (d) Facilities office building, on or about 11 April 2024 and at times thereof: Employees were exposed to an exit route path lighting that is not operational. Resulting in trip/fall  and burn injuries from trying to exit building during an emergency event.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.178 L04 III

Other-than-serious 2 instances 5 exposed
Issued
May 23, 2024
Abate by
Jun 20, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.178(l)(4)(iii):An evaluation of each powered industrial truck operator's performance was not conducted at least once every three years.  (a) Facility maintenance shop, on or about 11 April 2024 and at times thereof: Employer failed to conduct power industrial truck operator performance refresher training at least every three years. Exposing employees to potential accidents and injuries to out dated safety practices for operator techniques, equipment operations and controls.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.212 A01

Other-than-serious 2 instances 6 exposed
Issued
May 23, 2024
Abate by
Jun 20, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.212(a)(1):Machine guarding was not provided to protect operator(s) and other employees from hazards created by in-going nip points, rotating parts, and/or flying chips and sparks:  (a) Facility maintenance shop, on or about 11 April 2024 and at times thereof:  Employees were exposed to struck by and caught in hazards such as flying chips and clothing caught in rotating parts. Employer failed to ensure that the drill press was equipped with a guard sufficient to protect the operator from the rotating chuck and flying debris created during operation.  (b)  Hotel facility maintenance area, on or about 11 April 2024 and at times thereof:  Employees were exposed to struck by and caught in hazards such as flying chips and clothing caught in rotating parts. Employer failed to ensure that the drill press was equipped with a guard sufficient to protect the operator from the rotating chuck and flying debris created during operation.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 B02

Other-than-serious 1 instance 3 exposed
Issued
May 23, 2024
Abate by
Jun 20, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.303(b)(2):Listed or�labeled electrical�equipment was�not used�or installed�in accordance�with instructions�included in�the listing�or labeling.  (a) Hotel facility maintenance  area, on or about 12 April 2024 and at times thereof: Employees were exposed to fire and electrical shock hazardous condition from a Relocatable power tap (power strips) were series-connected (daisy-chained) to extension cords or other power strips resulting in potential minor burns and electrical shock.   For Reference:  Underwriters Laboratories (UL), refers to power strips as Relocatable Power Taps (RPTs) and, in its "General Information for Electrical Equipment Directory" (sometimes called the UL white book or UL Directory) contains instructions that require UL-listed RPTs to be directly connected to a permanently installed branch circuit receptacle; they are not to be series-connected to other RPTs or connected to extension cords.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 E01 I

Other-than-serious 3 instances 100 exposed
Issued
May 23, 2024
Abate by
Jun 20, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.1200(e)(1)(i): The employer did not compile a list of the hazardous chemicals known to be present using a product identifier that was referenced on the appropriate safety data sheet:  (a) Facility maintenance area, on or about 11 April 2024 and at times thereof: Employer fail to provide compiled list of known hazardous chemicals to be present using a product identifier that was not referenced on the appropriate safety data sheet exposing employees  to potential eye and skin injuries.  (b)  Warehouse, on or about 11 April 2024 and at times thereof: Employer fail to provide compiled list of known hazardous chemicals to be present using a product identifier that was not referenced on the appropriate safety data sheet exposing employees  to potential eye and skin injuries.  (c) H/R building, on or about 11 April 2024 and at times thereof: Employer fail to provide compiled list of known hazardous chemicals to be present using a product identifier that was not referenced on the appropriate safety data sheet exposing employees  to eye and skin injuries.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 F10

Other-than-serious 3 instances 15 exposed
Issued
May 23, 2024
Abate by
Jun 20, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.1200(f)(10): The employer did not ensure that workplace labels or other forms of warnings were legible.  (a) Shop area,  on or about 11 April 2024 and at times thereof: Employees were exposed to potential serious injuries from numerous unlabeled contains or labels that were not legible resulting to unknown chemical hazards which could cause serious burns or eye injuries or illnesses.  (b)H/R building, on or about 11 April 2024 and at times thereof: Employees were exposed to potential serious injuries from numerous unlabeled contains or labels that were not legible resulting to unknown chemical hazards which could cause serious burns or eye injuries or illnesses.  (c) Warehouse area, on or about 11 April 2024 and at times thereof: Employees were exposed to serious injuries from numerous unlabeled contains or labels that were not legible resulting to unknown chemical hazards which could cause serious burns or eye injuries or illnesses.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0