Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: THE TAPCO TUBE COMPANY

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of THE TAPCO TUBE COMPANY in 10748 S. WATER STREET EXTENSION, MEADVILLE, PA 16335 (NAICS 331210). OSHA activity number 347438335.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch The Tapco Tube Company — free Get an email when a new federal OSHA severe-injury report for The Tapco Tube Company is published. One employer, no account, unsubscribe in one click.
Site address
10748 S. WATER STREET EXTENSION
City
MEADVILLE
State
PA
ZIP
16335
Mailing
10748 S. WATER STREET EXTENSION, MEADVILLE, PA 16335
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331210
Employees
65
Ownership type
A

3 citations on file for this inspection.

1910.22 A02

Serious Gravity 1 1 instance 5 exposed
Issued
Sep 25, 2024
Abate by
Oct 18, 2024
Penalty
Initial $4,113 · Current $2,879 Reduced
29 CFR  1910.22(a)(2): The employer did not ensure that the  floor of each workroom is maintained in a clean and, to the extent feasible, in a dry condition. The employer did not ensure that when wet processes are used, drainage is be maintained and, to the extent feasible, dry standing places, such as false floors, platforms, and mats are provided.  A.) The Tapco Tube Company, Line 1, On or about 4/24/24 and times prior thereto: Accumulation of coolant from the tube mill operation was located on the floor around the tube mill.  The accumulation presented a slip and fall hazard.  ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below).  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $2879.1
  • — Z (S) $4113

1910.145 E02

Other-than-serious 2 instances 6 exposed
Issued
Sep 25, 2024
Abate by
Oct 18, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.145(e)(2):The wording of signs was not easily read and concise.  A.) The Tapco Tube Company, Tooling Area, On or about 4/24/24 and times prior thereto: Caution Label attached to equipment were not legible due to the message being worn off.  Equipment Includes but is not limited to Trak DPM Serial # 96-2350.   B.) The Tapco Tube Company, Line 1, On or about 4/24/24 and times prior thereto: Danger labels attached to equipment were not legible due to the message being worn off.  Equipment including but is not limited to the blue bonnet on the tube mill.  ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below).  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.145 F03

Other-than-serious 1 instance 3 exposed
Issued
Sep 25, 2024
Abate by
Oct 18, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.145(f)(3): Tags were not used as a means to prevent accidental injury or illness to employees who were exposed to hazardous or potentially hazardous conditions, equipment or operations which were out of the ordinary, unexpected or not readily apparent:  A.)The Tapco Tube Company, Maintenance Shop, On or about 4/24/24 and times prior thereto:  Power cords with damage were not examined, fixed, and/or taken out of service.  The power cord being used to power the automatic mode sensor on the Bridgeport Mill Serial #155707 was wrapped with electrical tape.   ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below).  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View The Tapco Tube Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347438335.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.