LYNDEN, WA —
OSHA Inspection: NOOKSACK NORTHWOOD CASINO
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NOOKSACK NORTHWOOD CASINO in 9750 NORTHWOOD ROAD, LYNDEN, WA 98264 (NAICS 713210). OSHA activity number 347592651.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NOOKSACK NORTHWOOD CASINO
- Site address
- 9750 NORTHWOOD ROAD
- City
- LYNDEN
- State
- WA
- ZIP
- 98264
- Mailing
- 9750 NORTHWOOD ROAD, LYNDEN, WA 98264
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 713210
- Employees
- 136
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.36 G02
- Issued
- Aug 23, 2024
- Abate by
- Oct 10, 2024
- Penalty
- Initial $5,288 · Current $3,173 Reduced
General-duty citation text
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points: a) Surveillance Manager's Office: On or about July 1, 2024, the placement of items including, the desk, boxes and paper, reduced the aisle way width to 11-20 inches exposing employees to egress hazards.
Recent events (2)
- — I (S) $3173
- — Z (S) $5288
1910.303 B02
- Issued
- Aug 23, 2024
- Abate by
- Sep 19, 2024
- Penalty
- Initial $5,288 · Current $3,173 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled equipment was not installed and used in accordance with any instructions included in the listing or labeling: a) Facility: On or about July 1, 2024, electrical equipment not used as listed and labeled as follows, exposing employees to electrical hazards: 1. Gift Store Manager's Office, where two relocatable power taps were daisy chained and used to supply power to office electronic equipment. 2. Gift Store, where a beige extension cord was daisy chained with a relocatable power tap and used to supply power to decorative display lights, holiday lights, and a spotlight lamp. 3. Loading Dock Workstation, where a beige extension cord was daisy chained with a relocatable power tap and used to supply power to an office computer, monitors, and a radio charging station. 4. Slot Maintenance Office, where a white extension cord was daisy chained with an APC back-up UPS and used to supply power to the HP DesignJet T630 Large Format Wireless Plotter Printer.
Recent events (2)
- — I (S) $3173
- — Z (S) $5288
1910.305 B02 I
- Issued
- Aug 23, 2024
- Abate by
- Oct 10, 2024
- Penalty
- Initial $5,288 · Current $3,173 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: a) Loading Dock Workstation: On or about July 1, 2024, receptacle used to supply power to a beige extension cord was not equipped with a cover, exposing employees to electrical hazards:
Recent events (2)
- — I (S) $3173
- — Z (S) $5288
1910.37 B02
- Issued
- Aug 23, 2024
- Abate by
- Oct 10, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": a) Observation Room Hallway: On or about July 1, 2024, the designated exit route door was not equipped with an exit sign, exposing employees to egress hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.37 B05
- Issued
- Aug 23, 2024
- Abate by
- Oct 10, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet): a) Observation Room Hallway: On or about July 1, 2024, door to the server room was not equipped with signage, exposing employees to egress hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.157 C01
- Issued
- Aug 23, 2024
- Abate by
- Oct 10, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: a) Maintenance Shop: On or about July 1, 2024, items including metal rods and a board, were stored in front of the fire extinguisher located adjacent to the emergency exit discharge door, exposing employees to fire hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Nooksack Northwood Casino
View Nooksack Northwood Casino's full OSHA safety record →
More inspections in this industry (NAICS 713210)
More inspections in WA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347592651.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.