DE PERE, WI —
OSHA Inspection: BELMARK, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of BELMARK, INC. in 633 HERITAGE ROAD, DE PERE, WI 54115 (NAICS 326112). OSHA activity number 347875221.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BELMARK, INC.
- Site address
- 633 HERITAGE ROAD
- City
- DE PERE
- State
- WI
- ZIP
- 54115
- Mailing
- 600 HERITAGE ROAD, DE PERE, WI 54115
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326112
- Employees
- 278
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.212 A03 II
- Issued
- Feb 14, 2025
- Abate by
- Mar 24, 2025
- Penalty
- Initial $16,550 · Current $11,585 Reduced
General-duty citation text
1910.212(a)(3)(ii) The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle. (a) On or about November 6, 2024 and thereafter, at an establishment located at 633 Heritage Road, De Pere, Wisconsin; in the Lamination Area, the energy control procedure utilized for de-energizing the DCM Lamination Equipment LM059 did not cover specific procedural steps when employees were engaged in startup and cleaning activities.
Recent events (2)
- — I (S) $11585
- — Z (S) $16550
1910.147 C07 I A
- Issued
- Feb 14, 2025
- Abate by
- Mar 24, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control. On or about November 6, 2024 and thereafter, at an establishment located at 633 Heritage Road, De Pere, Wisconsin; in the Lamination Area, employees authorized to perform set up and cleaning activities on the DCM LM059 laminator were not trained as an authorized employee under the control of hazardous energy.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 D
- Issued
- Feb 14, 2025
- Abate by
- Mar 24, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): (a) On or about November 6, 2024, at an establishment located at 633 Heritage Road, De Pere, Wisconsin; in the Lamination Area, employees were exposed to machine hazards associated with moving parts when they engaged in set-up activities on the DCM, Model: Laminstar, LM059. The employer did not ensure that employees implemented energy control application steps or equivalent protective measures prior to allowing them to set-up. The machine was not deenergized prior to the employee engaging in the servicing / maintenance activity. (b) On or about November 9, 2024 and thereafter, at an establishment located at 633 Heritage Road, De Pere, Wisconsin, in the Lamination Area, employees were exposed to machine hazards associated with moving parts when they engaged in cleaning activities on the DCM, Model: Laminstar, LM059. The employer did not ensure that employees implemented energy control application steps or equivalent protective measures prior to allowing them to clean. The machine was not deenergized prior to the employee engaging in the servicing/maintenance activity. As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], lockout/tagout device application [1910.147(d)(4)], dissipation of residual energy [1910(d)(5)(i)], and verification of isolation [1910.147(d)(6)] were not implemented to protect employees from machine hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Belmark, INC.
View Belmark, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 326112)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347875221.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.