Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CRYSTAL FINISHING SYSTEMS, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of CRYSTAL FINISHING SYSTEMS, INC. in 2608 ROSS AVENUE, SCHOFIELD, WI 54476 (NAICS 423510). OSHA activity number 348049669.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Crystal Finishing Systems, INC. — free Get an email when a new federal OSHA severe-injury report for Crystal Finishing Systems, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2608 ROSS AVENUE
City
SCHOFIELD
State
WI
ZIP
54476
Mailing
4704 BAYBERRY STREET, SCHOFIELD, WI 54476
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423510
Employees
540
Ownership type
A

2 citations on file for this inspection.

1910.147 C07 I A

Deleted Serious Gravity 5 3 instances 5 exposed
Issued
Apr 11, 2025
Abate by
May 9, 2025
Penalty
Initial $10,403 · Current $0 Reduced
29 CFR  1910.147(c)(7)(i)(A): Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.  a) On or about March 2, 2025, at the establishment located at 2608 Ross Avenue, Schofield, Wisconsin; the employer did not ensure that employees entering the Main Line Cure Oven to clean up fallen louvers were trained as authorized employees under the control of hazardous energy, exposing employees to hazards, such as but not limited to mechanical and natural gas.  b) On or about February 12, 2025, at the establishment located at 2608 Ross Avenue, Schofield, Wisconsin; the employer did not ensure that an employee entering the Main Line Blow Off Dry Oven to pick up fallen parts was trained as an authorized employee under the control of hazardous energy, exposing an employee to hazards, such as but not limited to mechanical, natural gas, and thermal.  c) On or about February 11, 2025, at the establishment located at 2608 Ross Avenue, Schofield, Wisconsin; the employer did not ensure that employees entering the Main Line Cure Oven to rehang parts were trained as authorized employees under the control of hazardous energy, exposing employees to hazards, such as but not limited to mechanical, natural gas, and thermal.
Recent events (2)
  • — I (S) $0
  • — Z (S) $10403

1910.147 D

Deleted Serious Gravity 5 4 instances 6 exposed
Issued
Apr 11, 2025
Abate by
May 9, 2025
Penalty
Initial $13,005 · Current $0 Reduced
29 CFR  1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6).   a) On or about March 2, 2025, at the establishment located at 2608 Ross Avenue, Schofield, Wisconsin; employees were exposed to hazards, such as but not limited to mechanical and natural gas when entering the Main Line Cure Oven to clean up fallen louvers. The employer did not ensure that employees had implemented energy control application steps or equivalent protective measures prior to allowing them to enter the Main Line Cure Oven. The machine was not isolated, such as but not limited to electrical and natural gas, prior to the employees engaging in the servicing and/or maintenance activity.  b) On or about February 28, 2025, at the establishment located at 2608 Ross Avenue, Schofield, Wisconsin; an employee was exposed to hazards, such as but not limited to natural gas when entering the Main Line Cure Oven to perform preventative maintenance work. The employer did not ensure that the employee had implemented energy control application steps or equivalent protective measures prior to allowing them to enter the Main Line Cure Oven. The machine was not isolated, such as but not limited to natural gas, prior to the employee engaging in the servicing and/or maintenance activity.  c) On or about February 12, 2025, at the establishment located at 2608 Ross Avenue, Schofield, Wisconsin; an employee was exposed to hazards, such as but not limited to mechanical, natural gas, and thermal when entering the Main Line Blow Off Dry Oven to pick up fallen parts. The employer did not ensure that the employee had implemented energy control application steps or equivalent protective measures prior to allowing them to enter the Main Line Blow Off Dry Oven. The machine was not isolated, such as but not limited to electrical, natural gas, and thermal prior to the employee engaging in the servicing and/or maintenance activity.  d) On or about February 11, 2025, at the establishment located at 2608 Ross Avenue, Schofield, Wisconsin; employees were exposed to hazards, such as but not limited to mechanical and natural gas when entering the Main Line Cure Oven to rehang parts. The employer did not ensure that employees had implemented energy control application steps or equivalent protective measures prior to allowing them to enter the Main Line Cure Oven. The machine was not isolated, such as but not limited to electrical and natural gas, prior to the employees engaging in the servicing and/or maintenance activity.  As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], lockout/tagout device application [1910.147(d)(4)], dissipation of residual energy [1910(d)(5)(i)], and verification of isolation [1910.147(d)(6)] were not implemented to protect employees from machine hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $13005

View Crystal Finishing Systems, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348049669.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.