OSHA Inspection: MOUNT JOY WIRE CORPORATION

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of MOUNT JOY WIRE CORPORATION in 1000 EAST MAIN STREET, MOUNT JOY, PA 17552 (NAICS 331222). OSHA activity number 348078551.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mount JOY Wire Corporation — free Get an email when a new federal OSHA severe-injury report for Mount JOY Wire Corporation is published. One employer, no account, unsubscribe in one click.
Site address
1000 EAST MAIN STREET
City
MOUNT JOY
State
PA
ZIP
17552
Mailing
1000 EAST MAIN STREET ATTN: ROB MUSCHLITZ, MOUNT JOY, PA 17552
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331222
Employees
107
Ownership type
A

4 citations on file for this inspection.

1910.134 G01 I A

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 17, 2025
Abate by
Jun 30, 2025
Penalty
Initial $8,511 · Current $8,511

Hazardous substances 1591

29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function:  a) 1000 East Main Street, Mount Joy, PA 17552 - Triple Lead Patenting (TLP) Department: On or about March 4, 2025, an employee was exposed to lead and was required to wear a tight-fitting half facepiece respirator and had facial hair that came between the sealing surface of the facepiece and the face.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $8511

1910.1025 E03 IV

Serious Gravity 5 1 instance 14 exposed
Issued
Jun 17, 2025
Abate by
Jul 23, 2025
Penalty
Initial $8,511 · Current $8,511

Hazardous substances 1591

29 CFR 1910.1025(e)(3)(iv): Written compliance programs for lead were not revised and updated annually to reflect the current status of the program:  a) 1000 East Main Street, Mount Joy, PA 17552: On or about March 4, 2025, the Comprehensive Lead Management Program had not been revised and updated at least annually to reflect the current status of the program. The program was last revised May 11, 2020.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $8511

1910.1025 F02 I

Serious Gravity 5 1 instance 14 exposed
Issued
Jun 17, 2025
Abate by
Jul 23, 2025
Penalty
Initial $0 · Current $0

Hazardous substances 1591

29 CFR 1910.1025(f)(2)(i): The employer did not implement a respiratory protection program in accordance with 29 CFR 1910.134(b) through (d) (except (d)(1)(iii)), and (f) through (m) for each employee required by 29 CFR 1910.1025 to use a respirator:  a) 1000 East Main Street, Mount Joy, PA 17552: On or about March 4, 2025, the employer had not implemented a written respiratory protection program when employees were required to wear tight-fitting half facepiece respirators in the Triple Lead Patenting (TLP) Department when exposed to lead.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $0

1910.1025 H01

Serious Gravity 5 2 instances 79 exposed
Issued
Jun 17, 2025
Abate by
Jun 30, 2025
Penalty
Initial $0 · Current $0

Hazardous substances 1591

29 CFR 1910.1025(h)(1): All surfaces were not maintained as free as practicable of accumulations of lead:  a) 1000 East Main Street, Mount Joy, PA 17552 - Climate controlled break room: On or about March 4, 2025, the eating surfaces of the tables were not maintained as free as practicable of accumulations of lead.  b) 1000 East Main Street, Mount Joy, PA 17552 - Non-climate controlled break room: On or about March 4, 2025, the eating surfaces of the tables and the button areas of the microwaves were not maintained as free as practicable of accumulations of lead.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $0

View Mount JOY Wire Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348078551.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.