LITTLE ROCK, AR —
OSHA Inspection: SAGE V FOODS, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of SAGE V FOODS, LLC in 5901 SLOANE DRIVE, LITTLE ROCK, AR 72206 (NAICS 311412). OSHA activity number 348538083.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SAGE V FOODS, LLC
- Site address
- 5901 SLOANE DRIVE
- City
- LITTLE ROCK
- State
- AR
- ZIP
- 72206
- Mailing
- 5901 SLOANE DRIVE, LITTLE ROCK, AR 72206
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311412
- Employees
- 266
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.147 C04 II
- Issued
- Mar 19, 2026
- Abate by
- Apr 14, 2026
- Penalty
- Initial $16,550 · Current $16,550
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): On or about October 2, 2025 and times prior thereto, on the Line 1 Dryer in the Instant Rice area, employees performed maintenance and servicing on a rotary airlock valve using deficient hazardous energy control procedures, in that: a) The procedures did not include clear and specific procedural steps for machine shut down. b) The procedures did not have clear and specific procedural steps for verifying isolation of energy sources. c) The procedures did not have clear and specific procedural steps for verifying controls are in the neutral position. d) The procedures did not have clear and specific procedural steps for applying power after lockout.
Recent events (2)
- — C (S) $16550
- — Z (S) $16550
1910.212 A02
- Issued
- Mar 19, 2026
- Penalty
- Initial $16,550 · Current $16,550
General-duty citation text
29 CFR 1910.212(a)(2): Guard(s) on machine(s) were not affixed to the machine or secured elsewhere when attachment to the machine was not possible: a) On or about September 28, 2025 and times prior thereto, on the Line 1 Dryer in the Instant Rice area, employees were working near a rotary airlock valve, which was inadequately guarded.
Recent events (2)
- — C (S) $16550
- — Z (S) $16550
1910.219 C04 I
- Issued
- Mar 19, 2026
- Penalty
- Initial $14,187 · Current $14,187
General-duty citation text
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft: a) On or about October 2, 2025 and times prior thereto, on the Line 1 Dryer in the Instant Rice area, employees were working near a rotary airlock valve where an unguarded keyed shaft projected more than half its diameter.
Recent events (2)
- — C (S) $14187
- — Z (S) $14187
1910.219 C04 II
- Issued
- Mar 19, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(c)(4)(ii): The unused keyway(s) of projecting shaft end(s) were not filled up or covered: a) On or about October 2, 2025 and times prior thereto, on the Line 1 Dryer in the Instant Rice area, employees were working near a rotary airlock valve where unfilled keyways were exposed.
Recent events (2)
- — C (S) $0
- — Z (S) $0
1910.147 C06 I
- Issued
- Mar 19, 2026
- Abate by
- Apr 14, 2026
- Penalty
- Initial $1,328 · Current $1,328
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: Employees performed servicing and maintenance on various machinery and equipment such as but not limited to Screw Conveyor Line 1. Lockout procedures had not been inspected at least annually, as follows: a) On or about October 2, 2025, and times prior thereto; b) On or about January 20, 2026, and times prior thereto.
Recent events (2)
- — C (O) $1328
- — Z (O) $1328
1910.147 C06 II
- Issued
- Mar 19, 2026
- Abate by
- Apr 14, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer did not certify that the periodic inspections have been performed: Employees were performing machine specific energy control procedures on the Screw Conveyor Line 1. The employer did not certify that annual periodic inspections of LOTO procedures were conducted, as follows: a) On or about October 2, 2025, and times prior thereto; b) On or about January 20, 2026, and times prior thereto.
Recent events (2)
- — C (O) $0
- — Z (O) $0
More inspections at Sage V Foods, LLC
View Sage V Foods, LLC's full OSHA safety record →
More inspections in this industry (NAICS 311412)
More inspections in AR
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348538083.