Clearwater, FL —
OSHA Injury Report: PEP : DYN - Clearwater
Injury · Other recordable case
At a glance
On , an injury at PEP : DYN - Clearwater in Clearwater, FL 33762 resulted in other recordable case. Employee was operator.
Where did this happen?
- Establishment
- PEP : DYN - Clearwater
- Parent company
- Carpenter Technology
- Street
- 14000 49th Street N
- City
- Clearwater
- State
- FL
- ZIP
- 33762
- On-site location
- Building 1-22TM
What was the outcome?
- Outcome
- Other recordable case (code 4)
- Type
- Injury (code 1)
Before the incident
Please see question below.
What happened
EE was processing a bar on the straight and cut the hot bar coming out of the arbor straightener got caught in the exit tray. He grabbed it to pull it to the side burned his hand and he reported he was wearing heat gloves that are rated to 400F. Measurements have shown that the bars come out of the arbor at a max of 300F.
Injury or illness
Burn - Heat (Scald) or Cold (Freeze) Hand Hand
Object or substance involved
300F bar
Summary line
Burn - Heat (Scald) or Cold (Freeze) Hand Hand 300F bar Contact with temperature extremes
Employee and industry
- Job description
- Operator
- SOC code
- 9999 — Uncoded
- NAICS code
- 331491
- NAICS vintage
- 2022
- Avg employees
- 207
- Total hours worked
- 423278
- EIN
- 232882270
- Establishment ID
- 237006
- Employer case #
- 107
When (timing detail)
- Date of incident
- Shift started
- 6:00:00.000
- Time of incident
- 11:30:00.000
- Submitted
- 13FEB24:14:19:00
Source
Data from OSHA ITA Form 300/301 electronic submissions, filing year unspecified. ITA Case Detail records are establishment-reported submissions, not OSHA inspections — no per-record IMIS deep link exists.