Phoenix, AZ —
OSHA Injury Report: Super Radiator Coils - Phoenix
Injury · Job transfer or restriction
At a glance
On , an injury at Super Radiator Coils - Phoenix in Phoenix, AZ 85034 resulted in job transfer or restriction. Employee was assembly in heat exchangers manufacturing.
Where did this happen?
- Establishment
- Super Radiator Coils - Phoenix
- Parent company
- Super Radiator Coils
- Street
- 2610 S 21st St
- City
- Phoenix
- State
- AZ
- ZIP
- 85034
- On-site location
- 2610 Brazing Department
What was the outcome?
- Outcome
- Job transfer or restriction (code 3)
- Type
- Injury (code 1)
- Days restricted or transferred
- 11
Before the incident
Employee was tightening bolts and nuts to the metal side panel of a coil using a standard size wrench.
What happened
She was holding the bolt nut with her left hand while using a standard size wrench with the right hand to tighten the bolt. Upon tightening the bolt the wrench slipped and she caught her fingers on the lower lip of the side panel resulting in the injury.
Injury or illness
Laceration to Right Hand Middle Finger.
Object or substance involved
Metal side pan edging.
Summary line
Laceration to Right Hand Middle Finger
Employee and industry
- Job description
- Assembly
- SOC code
- 51-2099 — Assemblers and Fabricators, All Other
- NAICS code
- 332410 — Heat exchangers manufacturing
- NAICS vintage
- 2022
- Avg employees
- 132
- Total hours worked
- 295337
- EIN
- 411533780
- Establishment ID
- 559031
- Employer case #
- 2023-03
When (timing detail)
- Date of incident
- Shift started
- 5:54:00.000
- Time of incident
- 6:40:00.000
- Submitted
- 23FEB24:18:45:00
Source
Data from OSHA ITA Form 300/301 electronic submissions, filing year unspecified. ITA Case Detail records are establishment-reported submissions, not OSHA inspections — no per-record IMIS deep link exists.