Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: MOUNT JOY WIRE CORPORATION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MOUNT JOY WIRE CORPORATION in 1000 EAST MAIN STREET, MOUNT JOY, PA 17552 (NAICS 000000). OSHA activity number 116155573.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mount JOY Wire Corporation for free Get an email when a new federal OSHA severe-injury report for Mount JOY Wire Corporation is published. One employer, no account, unsubscribe in one click.
Site address
1000 EAST MAIN STREET
City
MOUNT JOY
State
PA
ZIP
17552
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Union (Y)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
000000
SIC code (legacy)
3315
Employees
120
Ownership type
Private (A)
Industry flags
Manufacturing safety.

6 citations on file for this inspection.

5(a)(1)

Serious Gravity 01 1 instance 1 exposed
Issued
Jan 8, 1998
Abate by
Apr 8, 2000
Penalty
Initial $1,200 · Current $700 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish
employment and a place of employment which were free from recognized
hazards that were
causing or likely to cause death or serious physical harm to employees in
that employees were
exposed burns from stack fire:
(a)Tempering Department - Employee(s) were exposed to the exhaust stack
fire
hazards from the oil tempering process.  No automatic fire protection
system was
provided in the exhaust stack in accordance with NFPA 86, 1995, sections
11-1.1
and 11-1.2.
AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT
METHOD TO CORRECT THIS HAZARD IS TO PROVIDE AN AUTOMATIC FIRE
PROTECTION SYSTEM.
Recent events (3)
  • · P (S) $700.00
  • · I (S) $700.00
  • · Z (S) $1200.00

1910.146 C04

Serious Gravity 01 1 instance 1 exposed
Issued
Jan 8, 1998
Abate by
Mar 15, 1998
Penalty
Initial $1,200 · Current $700 Reduced
Recent events (2)
  • · I (S) $700.00
  • · Z (S) $1200.00

1910.132 D01

Other-than-serious Gravity 01 1 instance 120 exposed
Issued
Jan 8, 1998
Abate by
Apr 15, 1998
Recent events (2)
  • · I (O)
  • · Z (O)

1910.179 J02 III

Other-than-serious Gravity 01 1 instance 1 exposed
Issued
Jan 8, 1998
Abate by
Feb 10, 1998

1910.179 M01

Other-than-serious Gravity 01 1 instance 1 exposed
Issued
Jan 8, 1998
Abate by
Feb 28, 1998
Recent events (2)
  • · I (O)
  • · Z (O)

1910.305 A02 IIIF

Other-than-serious Gravity 01 1 instance 1 exposed
Issued
Jan 8, 1998
Abate by
Mar 15, 1998
Recent events (2)
  • · I (O)
  • · Z (O)

View Mount JOY Wire Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 116155573.