Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CROWN BATTERY MFG. CO.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of CROWN BATTERY MFG. CO. in 1445 MAJESTIC DRIVE, FREMONT, OH 43420 (NAICS 335911). OSHA activity number 332836378.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Crown Battery MFG. CO. — free Get an email when a new federal OSHA severe-injury report for Crown Battery MFG. CO. is published. One employer, no account, unsubscribe in one click.
Site address
1445 MAJESTIC DRIVE
City
FREMONT
State
OH
ZIP
43420
Mailing
P. O. BOX 990, FREMONT, OH 43420
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
335911
Employees
465
Ownership type
A

2 citations on file for this inspection.

1910.132 A

Serious Gravity 5 1 instance 50 exposed
Issued
Aug 28, 2012
Abate by
Sep 12, 2012
Penalty
Initial $4,675 · Current $2,338 Reduced

Hazardous substances 1591

29 CFR 1910.132(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, and maintained in a sanitary and reliable condition wherever it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact:    a) Crown Battery Mfg. Co. - Fremont, Ohio: On or about March 29, 2012, the employer failed to provide adequate personal protective equipment to employees adding lead pigs and scrap to lead pots in SLI Casting. Employees were exposed to hazards from molten lead splashes at approximately 900 degrees Fahrenheit while wearing a polyester/ cotton blend uniform.
Recent events (2)
  • — I (S) $2337.5
  • — Z (S) $4675

1910.138 A

Serious Gravity 5 1 instance 50 exposed
Issued
Aug 28, 2012
Abate by
Sep 12, 2012
Penalty
Initial $0 · Current $0

Hazardous substances 1591

29 CFR 1910.138(a): The employer did not select and require employees to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasions; punctures; chemical burns; thermal burns; and harmful temperature extremes:    a) Crown Battery Mfg. Co. - Fremont, Ohio: On or about March 29, 2012, the employer failed to provide adequate hand protection to employees adding lead pigs and scrap to lead pots in SLI Casting. Employees were exposed to hazards from molten lead splashes at approximately 900 degrees Fahrenheit while wearing leather gloves which had a cloth back and cuff.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Crown Battery MFG. CO.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 332836378.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.