Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SAN PABLO LYTTON CASINO

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SAN PABLO LYTTON CASINO in 13255 SAN PABLO AVENUE, SAN PABLO, CA 94806 (NAICS 713210). OSHA activity number 334228434.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch SAN Pablo Lytton Casino — free Get an email when a new federal OSHA severe-injury report for SAN Pablo Lytton Casino is published. One employer, no account, unsubscribe in one click.
Site address
13255 SAN PABLO AVENUE
City
SAN PABLO
State
CA
ZIP
94806
Mailing
13255 SAN PABLO AVENUE, SAN PABLO, CA 94806
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
713210
Employees
400
Ownership type
A

3 citations on file for this inspection.

1910.215 A04

Serious Gravity 1 1 instance 10 exposed
Issued
May 23, 2012
Abate by
May 29, 2012
Penalty
Initial $2,250 · Current $2,250
29 CFR 1910.215(a)(4): Work rests were not kept adjusted closely to the wheel with a maximum opening of one-eighth inch to prevent the work from being jammed between the wheel and the rest, which may cause wheel breakage:  (a) In the maintenance shop on or about May 9, 2012, and at times prior thereto, the work rest was 7/8s inch from the abrasive wheel on a Dayton 6 Variable Speed Bench Grinder.  The wheel was used to grind small metal tools and parts.
Recent events (1)
  • — Z (S) $2250

1910.303 G02 II

Other-than-serious 1 instance 10 exposed
Issued
May 23, 2012
Abate by
May 29, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(2)(ii): In locations where electric equipment was likely to be exposed to physical damage, enclosures or guards were not so arranged and of such strength as to prevent such damage:    (a) In the maintenance shop, on or about May 9, 2012, and at times prior thereto, four foot long florescent bulbs were located 78 inches from the floor in a fixture and were not protected from accidental contract.  A DeWalt compound mitre saw was used under the bulbs.
Recent events (1)
  • — Z (O) $0

1910.305 G01 IV A

Other-than-serious 1 instance 10 exposed
Issued
May 23, 2012
Abate by
May 29, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used as a substitute for the fixed wiring of a structure:  (a) In the maintenance shop, on or about May 9, 2012, and at times prior thereto, a flexible cord was used to power outlets in a 4 inch square box that was mounted to the wall.  The outlets powered a 110 VAC DeWalt compound mitre saw.
Recent events (1)
  • — Z (O) $0

View SAN Pablo Lytton Casino's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334228434.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.