Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,288Inspections Most recent open 2026-07-24 Last loaded 2026-07-29

OSHA Inspection: XIANG WANG CONSTRUCTION CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of XIANG WANG CONSTRUCTION CORPORATION in CHALAN CHIBA LOT R91, YIGO, GU 96929 (NAICS 236115). OSHA activity number 335325106.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Xiang Wang Construction Corporation — free Get an email when a new federal OSHA severe-injury report for Xiang Wang Construction Corporation is published. One employer, no account, unsubscribe in one click.
Site address
CHALAN CHIBA LOT R91
City
YIGO
State
GU
ZIP
96929
Mailing
PO BOX 315752, TAMUNING, GU 96931
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
2
Ownership type
A

5 citations on file for this inspection.

1926.25 A

Serious Gravity 1 1 instance 2 exposed
Issued
Jan 16, 2013
Abate by
Feb 12, 2013
Penalty
Initial $1,200 · Current $1,200
29 CFR 1926.25(a): During the course of construction, alteration, or repairs, form or scrap lumber with protruding nails was not kept clear from work areas:    (a) Construction Site: On or about July 23, 2012, and at times prior thereto, employees were exposed to laceration and impalement hazards while walking and working around scrap wood with vertically protruding nails.
Recent events (1)
  • — Z (S) $1200

1926.300 B01

Serious Gravity 1 1 instance 2 exposed
Issued
Jan 16, 2013
Abate by
Feb 12, 2013
Penalty
Initial $1,200 · Current $1,200
29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use:    (a) Construction Site: On or about July 23, 2012, and at times prior thereto, employees were exposed to flying parts and pieces while using a Makita power operated angle grinder, serial number 08643464, without a guard.
Recent events (1)
  • — Z (S) $1200

1926.404 B01 II

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 16, 2013
Abate by
Feb 12, 2013
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection:       (a) Construction Site: On or about July 23, 2012, and at times prior thereto, employees were exposed to electrical shock hazards while using the Makita power operated angle grinder that was plugged into an outlet without ground fault circuit interrupters.
Recent events (1)
  • — Z (S) $2000

1926.404 F06

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 16, 2013
Abate by
Feb 12, 2013
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous:    (a) Construction Site: On or about July 23, 2012, and at times prior thereto, employees were exposed to electrical shock hazards while using an ungrounded extension cord for power tools.
Recent events (1)
  • — Z (S) $2000

1926.405 G02 IV

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 16, 2013
Abate by
Feb 12, 2013
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:    (a) Construction Site: On or about July 23, 2012, and at times prior thereto, employees were exposed to electrical shock hazards while using power cords without strain relief.
Recent events (1)
  • — Z (S) $2000

View Xiang Wang Construction Corporation's full OSHA safety record →