SHEBOYGAN, WI —
OSHA Inspection: WATRY INDUSTRIES LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of WATRY INDUSTRIES LLC in 3312 LAKESHORE DRIVE, SHEBOYGAN, WI 53081 (NAICS 331524). OSHA activity number 337190789.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WATRY INDUSTRIES LLC
- Site address
- 3312 LAKESHORE DRIVE
- City
- SHEBOYGAN
- State
- WI
- ZIP
- 53081
- Mailing
- 3312 LAKESHORE DRIVE, SHEBOYGAN, WI 53081
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331524
- Employees
- 100
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C04 I
- Issued
- Mar 6, 2013
- Abate by
- Apr 1, 2013
- Penalty
- Initial $2,380 · Current $1,666 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) On or about November. 14, 2012 an employee changed a band saw blade on the SWB009 band saw in the foundry without implementing any form of energy control procedures such as lockout tagout or unplugging the band saw from its power source while changing the blade. Abatement Certification and Abatement Documentation Required.
Recent events (2)
- — I (S) $1666
- — Z (S) $2380
1910.305 B01
- Issued
- Mar 6, 2013
- Abate by
- Mar 16, 2013
- Penalty
- Initial $2,975 · Current $2,083 Reduced
General-duty citation text
29 CFR 1910.305(b)(1): Openings through which conductors enter boxes, cabinets, or fittings were not effectively closed: a) On or about November 2, 2012 the flexible cord entering an electrical box powering the trim table in Bay 4 was not effectively closed, exposing the live conductors. Abatement Certification and Abatement Documentation Required.
Recent events (2)
- — I (S) $2082.5
- — Z (S) $2975
1910.305 G02 III
- Issued
- Mar 6, 2013
- Abate by
- Mar 16, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: a) On or about November 2, 2012 a flexible cord was pulled away from the attachment plug on top of the trim table in the foundry area, exposing the energized conductors. Abatement Certification and Abatement Documentation Required.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Watry Industries LLC
View Watry Industries LLC's full OSHA safety record →
More inspections in this industry (NAICS 331524)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337190789.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.