Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: VIGOR ALASKA, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of VIGOR ALASKA, LLC in 3801 TONGASS AVENUE, KETCHIKAN, AK 99901 (NAICS 336611). OSHA activity number 339810152.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Vigor Alaska, LLC — free Get an email when a new federal OSHA severe-injury report for Vigor Alaska, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
VIGOR ALASKA, LLC
Site address
3801 TONGASS AVENUE
City
KETCHIKAN
State
AK
ZIP
99901
Mailing
3801 TONGASS AVENUE, KETCHIKAN, AK 99901
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336611
Employees
110
Ownership type
A

7 citations on file for this inspection.

1910.212 B

Deleted Serious Gravity 1 1 instance 2 exposed
Issued
Jun 27, 2014
Abate by
Jul 31, 2014
Penalty
Initial $2,295 · Current $0 Reduced
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving.   Carpenter Shop, Bay side:  On or about 10 June 2014 and times prior thereto, The DeWALT 8" Bench Grinder, Model Number DW758 was not secured to the work bench. This condition exposed employees to stuck by hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2295

1915.72 A01

Serious Gravity 1 2 instances 2 exposed
Issued
Jun 27, 2014
Penalty
Initial $2,295 · Current $1,721 Reduced
29 CFR 1915.72(a)(1): ladders with broken or missing Rungs or steps, broken or split side rails, or other faulty or defective construction were used.   (A)  Assembly Building, Bay Area: Oil Response Skimmer:  On or about 10 June 2014 and times prior, the six foot Green Bull ladder had a damaged rung.   This condition exposed employees to a fall hazard.   (B)  Assembly Building, Bay Area: Oil Response Skimmer: On or about 10 June 2014 and times prior, the six foot Louisville ladder had a damaged rung.   This condition exposed employees to a fall hazard.
Recent events (2)
  • — I (S) $1721.25
  • — Z (S) $2295

1910.305 B01 II

Serious Gravity 1 3 instances 10 exposed
Issued
Jun 27, 2014
Penalty
Initial $2,295 · Current $1,721 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed.  (a) Assembly Building, ESAB Table:  On or about 9 June 2014 and times prior thereto, electrical panel 1HB UOM 109 was missing two knock outs.  This condition exposed employees to an electrical shock and burn hazard.  (b) Assembly Building, Machine Shop:  On or about 9 June 2014 and times prior thereto, electrical junction box was missing a knock out.  This condition exposed employees to an electrical shock and burn hazard.
Recent events (2)
  • — I (S) $1721.25
  • — Z (S) $2295

1910.305 J01 I

Serious Gravity 1 1 instance 10 exposed
Issued
Jun 27, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(j)(1)(i): Fixtures, lampholders, lamps, rosettes, and receptacles located had live parts normally exposed to employee contact.  Drying Area:  On or about 10 June 2014 and times prior thereto, the 120 volt electrical outlet 1LB-6 face plate was deformed.  This condition exposed employees to an electrical shock and burn hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV A

Serious Gravity 1 1 instance 5 exposed
Issued
Jun 27, 2014
Abate by
Jul 31, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure.  Assembly Building, Store Room:  On or about 10 June 2014 and times prior thereto a 120 volt orange extension cord was attached to the wall and routed over the doorway as permanent wiring.  This condition exposed employees to an electrical shock and burn hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 F05 I

Other-than-serious 2 instances 10 exposed
Issued
Jun 27, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein.  (a) Assembly Building, ERAB Table area:  On or about 9 June 2014 and times prior thereto an unattended plastic bottle; containing an unknown chemical substance was not marked identifying the product and the hazard warnings associated with it.  This condition exposed employees to chemical burns, poisoning, and skin dermatitis.  (b) Assembly Building, Electrician shop:  On or about 10 June 2014 and times prior thereto an unattended plastic bottle; containing an unknown chemical substance was not marked identifying the product and the hazard warnings associated with it.  This condition exposed employees to chemical burns, poisoning, and skin dermatitis.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1915.89 C07 IV F

Other-than-serious 2 instances 86 exposed
Issued
Jun 27, 2014
Abate by
Jul 31, 2014
Penalty
Initial $0 · Current $0
29 CFR 1915.89(c)(7)(iv)(F):  The lockout and tags-plus systems log did not contain the date that the lockout/tags-plus system was removed.  Tool room:  On or about 10 June 2014 and times prior thereto, The Lock Out Tag Out log was not annotated when locks had been removed. Locks y-12 (hyd shop) and y-8 ( Pier Station #1) were removed from the equipment and were not logged in.  This condition exposed employees to misinformation on equipment status.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Vigor Alaska, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339810152.