Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: A&F CONSTRUCTION CARPENTERS, CORP.,

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of A&F CONSTRUCTION CARPENTERS, CORP., in 316 PARK AVE, SAINT CHARLES, IL 60174 (NAICS 238130). OSHA activity number 339979031.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch A&F Construction Carpenters, Corp., — free Get an email when a new federal OSHA severe-injury report for A&F Construction Carpenters, Corp., is published. One employer, no account, unsubscribe in one click.
Site address
316 PARK AVE
City
SAINT CHARLES
State
IL
ZIP
60174
Mailing
619 N. LINCOLN AVE. APT. 2, AURORA, IL 60505
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
5
Ownership type
A

4 citations on file for this inspection.

1926.102 A01

Serious Gravity 1 1 instance 1 exposed
Issued
Oct 17, 2014
Penalty
Initial $1,200 · Current $1,200
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents:  On or about October 2, 2014, at the above addressed jobsite, employees using pneumatic nail guns did not wear safety glasses, thereby exposing employees to the hazards associated with eye injuries.  There is no abatement certification or documentation required for this item.
Recent events (1)
  • — Z (S) $1200

1926.404 B01 I

Serious Gravity 5 1 instance 5 exposed
Issued
Oct 17, 2014
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites:  On or about October 2, 2014, at the above addressed jobsite, employees were exposed to electrical shock/electrocution hazards when using extension cords which were plugged in to a portable generator. A ground fault circuit interrupter was not used and the employer did not institute an assured equipment grounding conductor program.  There is no abatement certification or documentation required for this item.
Recent events (1)
  • — Z (S) $2000

1926.501 B13

Serious Gravity 10 1 instance 5 exposed
Issued
Oct 17, 2014
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):  Instance 1.     On or about October 2, 2014, at the above addressed jobsite, employees constructing an exterior wall on a residential property were not protected from falling, exposing employees to fall hazards of approximately fourteen (14) feet.  Instance 2.    On or about October 2, 2014, at the above addressed jobsite, guardrails were missing from the second floor windows while employees were discarding material and debris through the windows, exposing employees to fall hazards of approximately fourteen (14) feet.  There is no abatement certification or documentation required for this item.
Recent events (1)
  • — Z (S) $2800

1926.1053 B01

Serious Gravity 5 1 instance 5 exposed
Issued
Oct 17, 2014
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  On or about October 2, 2014, at the above addressed jobsite, the portable extension ladder used to access the working level did not extend at least three (3) feet above the upper landing surface, thereby exposing employees to the hazards associated with falls of approximately fourteen (14) feet.  There is no abatement certification or documentation required for this item.
Recent events (1)
  • — Z (S) $2000

View A&F Construction Carpenters, Corp.,'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339979031.