OSHA Inspection: AMERICAN SYNTHETIC FIBER, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of AMERICAN SYNTHETIC FIBER, LLC in 312 SOUTH HOLLAND DRIVE, PENDERGRASS, GA 30567 (NAICS 313230). OSHA activity number 340130814.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch American Synthetic Fiber, LLC — free Get an email when a new federal OSHA severe-injury report for American Synthetic Fiber, LLC is published. One employer, no account, unsubscribe in one click.
Site address
312 SOUTH HOLLAND DRIVE
City
PENDERGRASS
State
GA
ZIP
30567
Mailing
312 SOUTH HOLLAND DRIVE, PENDERGRASS, GA 30567
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
313230
Employees
60
Ownership type
A

4 citations on file for this inspection.

1910.147 C06 I A

Serious Gravity 5 3 instances 20 exposed
Issued
Jan 15, 2015
Abate by
Mar 5, 2015
Penalty
Initial $3,273 · Current $2,291 Reduced
29 CFR 1910.147(c)(6)(i)(A): The periodic inspection of the energy control procedure was not performed by an authorized employee other than the one utilizing the energy control procedure being inspected.  On 12/9/14, at the Pendergrass facility, the employer did not ensure the periodic inspection of lockout procedures was performed by an authorized employee other than the employee utilizing the procedure being inspected.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $2291
  • — Z (S) $3273

1910.147 C06 I B

Serious Gravity 10 3 instances 15 exposed
Issued
Jan 15, 2015
Abate by
Mar 5, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i)(B): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.  On 12/9/14, at the Pendergrass facility, periodic inspections of the Lockout procedures did not correct deficiencies in the procedures. i.e. procedures did not list all energies or magnitudes of energy on various equipment including Line 2 Spin Heads 8-14, Line 2 Crimper, and Line 2 GR Balers.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C07 I A

Serious Gravity 10 5 instances 60 exposed
Issued
Jan 15, 2015
Abate by
Mar 5, 2015
Penalty
Initial $5,390 · Current $3,770 Reduced
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation.  On 12/9/14, at the Pendergrass facility, authorized employees did not receive training in the recognition of all energies and energy magnitudes necessary for energy isolation.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $3770
  • — Z (S) $5390

1910.147 F03 II D

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 15, 2015
Abate by
Feb 11, 2015
Penalty
Initial $3,273 · Current $2,291 Reduced
29 CFR 1910.147(f)(3)(ii)(D): Each authorized employee shall affix a personal lockout or tagout device to the group lockout device prior to working on the machine or equipment.  On or about 12/9/14, at the Pendergrass facility, employees were exposed to unexpected energy start up as each authorized employee was not required to attach a lock to energies when servicing/maintaining/cleaning equipment and instead two employees would use a single lock when locking out equipment for maintenance purposes.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $2291
  • — Z (S) $3273

View American Synthetic Fiber, LLC's full OSHA safety record →