On , OSHA opened a planned safety inspection of FLEET READINESS CENTER SOUTH WEST in BLDG. 472, CORONADO, CA 92135 (NAICS 488190). OSHA activity number 340179886.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FLEET READINESS CENTER SOUTH WEST
- Site address
- BLDG. 472
- City
- CORONADO
- State
- CA
- ZIP
- 92135
- Mailing
- NAS NORTH ISLAND BLDG 334 BOX 357058, SAN DIEGO, CA 92135
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 488190
- Employees
- 135
- Ownership type
- D
Citations
5 citations on file for this inspection.
1910.212 A01
- Issued
- Apr 1, 2015
- Abate by
- Oct 31, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) Building 472, Machine Shop: On or about January 14, 2015, a Bridgeport Milling Machine, Model: Ram, Serial Number J116421, Voltage: 230, and Amp 4.4 did not have a guard to protect the rotating parts. Employees were exposed to catching their fingers and hand at the unguarded disk. (b) Building 472, Machine Shop: On or about January 14, 2015, a Cincinnati Drill Press, Model 24 inch pedestal, Serial Number 2L3674, Voltage: 208-220, and Amp 15.2 did not have a guard to protect the rotating parts. Employees were exposed to catching their fingers and hand at the unguarded disk. (c) Building 472, Machine Shop: On or about January 14, 2015, a Fosdick Drill Press, Model Radial, Serial Number: 171-051353, Voltage 220, and Amp 8.4 did not have a guard to protect the rotating parts. Employees were exposed to catching their fingers and hand at the unguarded disk. (d) Building 472, Machine Shop: On or about January 14, 2015, a Bridgeport Hardinge Milling Machine, Model Ram, Serial Number 041341, Voltage 230, and Amp 6.2 did not have a guard to protect the rotating parts. Employees were exposed to catching their fingers and hand at the unguarded disk.
Recent events (1)
- — Z (S) $0
1910.242 B
- Issued
- Apr 1, 2015
- Abate by
- Oct 31, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning. Compressed air was not used for cleaning purposes except where reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment. Building 379, Machine Shop: On or about January 14, 2015, an employee did not use a compressed air nozzle less than 30 p.s.i. The nozzle was connected to air pressure gauge reading 95 psi. The compressed air was used for blowing or cleaning metal chips inside the HARDINGE Conquest T42 Automation Machine, Part Number N157812M1306-101, Serial Number 7873. Employee was exposed to High-pressure injection of particles or liquids damaging eyes or skin.
Recent events (1)
- — Z (S) $0
1904.30 A
- Issued
- Apr 1, 2015
- Abate by
- Oct 31, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1904.30(a): Basic requirement. Employer did not keep a separate OSHA 300 Log for each establishment that is expected to be in operation for one year or longer. (a) Fleet Readiness Center Southwest, Building 472: On February 1, 2015 a separate OSHA Form 300 was not maintained for the calendar year 2014.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1904.32 A03
- Issued
- Apr 1, 2015
- Abate by
- Oct 31, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1904.32(a)(3): A record of OSHA Form 300A Summary of Work Related Injuries and Illnesses was not certified: (a) Fleet Readiness Center Southwest, Building 27: On February 1, 2015 a separate OSHA Form 300A was not certified for the calendar year 2014.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1904.32 A04
- Issued
- Apr 1, 2015
- Abate by
- Oct 31, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1904.32(a)(4): A record of OSHA Form 300A Summary of Work Related Injuries and Illnesses was not posted: (a) Fleet Readiness Center Southwest, Building 27: On February 1, 2015 a separate OSHA Form 300A was not posted for the calendar year 2014.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Fleet Readiness Center South West
View Fleet Readiness Center South West's full OSHA safety record →
More inspections in this industry (NAICS 488190)
More inspections in CA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340179886.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.