Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ASANUMA CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ASANUMA CORPORATION in ABC STORE RENOVATION PROJECT MICRONESIA MALL, MARINE CORPS DRIVE, DEDEDO, GU 96929 (NAICS 236220). OSHA activity number 340753979.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Asanuma Corporation — free Get an email when a new federal OSHA severe-injury report for Asanuma Corporation is published. One employer, no account, unsubscribe in one click.
Establishment
ASANUMA CORPORATION
Site address
ABC STORE RENOVATION PROJECT MICRONESIA MALL, MARINE CORPS DRIVE
City
DEDEDO
State
GU
ZIP
96929
Mailing
PO BOX 22108 GMF, BARRIGADA, GU 96921
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
15
Ownership type
A

4 citations on file for this inspection.

1926.403 B02

Serious Gravity 1 1 instance 2 exposed
Issued
Jul 28, 2015
Abate by
Aug 5, 2015
Penalty
Initial $1,020 · Current $714 Reduced
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:  In the warehouse area, electrical equipment was not installed as designed to be installed as the wires that protruded from the metallic sheathed cable were stripped back and inserted into a 110 VAC receptacle in an electrical box mounted to a wood stand.  The wires powered a 110 VAC fluorescent light that rested against the floor and a wall.  Employees were exposed to the hazard of contacting electicity.
Recent events (2)
  • — I (S) $714
  • — Z (S) $1020

1926.404 B01 I

Serious Gravity 1 1 instance 2 exposed
Issued
Jul 28, 2015
Abate by
Aug 5, 2015
Penalty
Initial $1,020 · Current $714 Reduced
29 CFR 1926.404(b)(1)(i): The employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites.  These requirements are in addition to any other requirements for equipment grounding conductors:  In the warehouse area, there was no ground-fault circuit-interrupters or assured equipment grounding conductor program to protect employees that used a 110 VAC drill to install a suspended ceiling from a scaffold platform.  The drill was powered through a flexible cord that was plugged into a temporay outlet on a wood stand.  The test button on the outlet would not trip the ground-fault circuit-interrupter in the outlet. Employees were exposed to the hazard of contacting electricity.
Recent events (2)
  • — I (S) $714
  • — Z (S) $1020

1926.451 F15

Serious Gravity 1 1 instance 1 exposed
Issued
Jul 28, 2015
Abate by
Aug 5, 2015
Penalty
Initial $1,020 · Current $714 Reduced
29 CFR 1926.451(f)(15): Ladders shall not be used on scaffolds to increase the working level height of employees, except on large area scaffolds where employers have satisfied the criteria in 29 CFR 1926.451(f)(15)(i)-(iv):  In the warehouse area, a 4 foot high step ladder was used on a mobile scaffold platform that was 4 feet wide by 6 feet long by 6 feet high.  Employees that used the ladder to install the suspended ceiling about two days prior to the OSHA inspection were exposed to the hazad of falling from heights that varied from about 7 to 8 feet to the concrete floor below.
Recent events (2)
  • — I (S) $714
  • — Z (S) $1020

1926.405 A02 II E

Other-than-serious 1 instance 2 exposed
Issued
Jul 28, 2015
Abate by
Aug 5, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.405(a)(2)(ii)(E): All lamps for general illumination were not protected from accidental contact or breakage:  In the warehouse area, two four foot long fluorescent light bulbs were not protected from accidental contact or breakage.  One end of the light fixture rested on the floor and the other end rested against the wall.  There was no cover or screen protecting the bulbs.  Employees that worked in the area with ladders, scaffolds, and other tools were exposed to the hazard of contacting electricity.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Asanuma Corporation's full OSHA safety record →