DEDEDO, GU —
OSHA Inspection: ASANUMA CORPORATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ASANUMA CORPORATION in ABC STORE RENOVATION PROJECT MICRONESIA MALL, MARINE CORPS DRIVE, DEDEDO, GU 96929 (NAICS 236220). OSHA activity number 340753979.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ASANUMA CORPORATION
- Site address
- ABC STORE RENOVATION PROJECT MICRONESIA MALL, MARINE CORPS DRIVE
- City
- DEDEDO
- State
- GU
- ZIP
- 96929
- Mailing
- PO BOX 22108 GMF, BARRIGADA, GU 96921
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 15
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.403 B02
- Issued
- Jul 28, 2015
- Abate by
- Aug 5, 2015
- Penalty
- Initial $1,020 · Current $714 Reduced
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: In the warehouse area, electrical equipment was not installed as designed to be installed as the wires that protruded from the metallic sheathed cable were stripped back and inserted into a 110 VAC receptacle in an electrical box mounted to a wood stand. The wires powered a 110 VAC fluorescent light that rested against the floor and a wall. Employees were exposed to the hazard of contacting electicity.
Recent events (2)
- — I (S) $714
- — Z (S) $1020
1926.404 B01 I
- Issued
- Jul 28, 2015
- Abate by
- Aug 5, 2015
- Penalty
- Initial $1,020 · Current $714 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(i): The employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors: In the warehouse area, there was no ground-fault circuit-interrupters or assured equipment grounding conductor program to protect employees that used a 110 VAC drill to install a suspended ceiling from a scaffold platform. The drill was powered through a flexible cord that was plugged into a temporay outlet on a wood stand. The test button on the outlet would not trip the ground-fault circuit-interrupter in the outlet. Employees were exposed to the hazard of contacting electricity.
Recent events (2)
- — I (S) $714
- — Z (S) $1020
1926.451 F15
- Issued
- Jul 28, 2015
- Abate by
- Aug 5, 2015
- Penalty
- Initial $1,020 · Current $714 Reduced
General-duty citation text
29 CFR 1926.451(f)(15): Ladders shall not be used on scaffolds to increase the working level height of employees, except on large area scaffolds where employers have satisfied the criteria in 29 CFR 1926.451(f)(15)(i)-(iv): In the warehouse area, a 4 foot high step ladder was used on a mobile scaffold platform that was 4 feet wide by 6 feet long by 6 feet high. Employees that used the ladder to install the suspended ceiling about two days prior to the OSHA inspection were exposed to the hazad of falling from heights that varied from about 7 to 8 feet to the concrete floor below.
Recent events (2)
- — I (S) $714
- — Z (S) $1020
1926.405 A02 II E
- Issued
- Jul 28, 2015
- Abate by
- Aug 5, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(E): All lamps for general illumination were not protected from accidental contact or breakage: In the warehouse area, two four foot long fluorescent light bulbs were not protected from accidental contact or breakage. One end of the light fixture rested on the floor and the other end rested against the wall. There was no cover or screen protecting the bulbs. Employees that worked in the area with ladders, scaffolds, and other tools were exposed to the hazard of contacting electricity.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Asanuma Corporation
View Asanuma Corporation's full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in GU
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340753979.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.