OSHA Inspection: ASANUMA CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ASANUMA CORPORATION in HOTEL NIKKO RESORT GUN BEACH ROAD, TAMUNING, GU 96931 (NAICS 236220). OSHA activity number 341698298.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Asanuma Corporation — free Get an email when a new federal OSHA severe-injury report for Asanuma Corporation is published. One employer, no account, unsubscribe in one click.
Establishment
ASANUMA CORPORATION
Site address
HOTEL NIKKO RESORT GUN BEACH ROAD
City
TAMUNING
State
GU
ZIP
96931
Mailing
P.O. BOX 22108, BARRIGADA, GU 96921
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
11
Ownership type
A

4 citations on file for this inspection.

1910.178 Q01

Serious Gravity 5 2 instances 4 exposed
Issued
Sep 30, 2016
Abate by
Oct 13, 2016
Penalty
Initial $2,850 · Current $1,995 Reduced
29 CFR 1910.178(q)(1): Any power-operated industrial truck not in safe operating condition was not taken out of service, and/or repairs were not made by authorized personnel:      a) On August 15, 2016, the Terex TH842C Turbo Materials Handler was operated with the seat and seat belt not securely mounted.
Recent events (2)
  • — I (S) $1995
  • — Z (S) $2850

1926.405 A02 II J

Serious Gravity 5 5 instances 25 exposed
Issued
Sep 30, 2016
Abate by
Oct 13, 2016
Penalty
Initial $2,850 · Current $1,710 Reduced
29 CFR 1926.405(a)(2)(ii)(J): Extension cord sets used with portable electric tools and appliances were not of the three-wire type:      a) On August 16, 2016, on the west side of the site, two-wire household type extension cords were used to power 110 VAC electric blower pumps, exposing employees to electrical hazards.
Recent events (2)
  • — I (S) $1710
  • — Z (S) $2850

1910.303 F02

Other-than-serious 1 instance 25 exposed
Issued
Sep 30, 2016
Abate by
Oct 13, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or over-current device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident.   a) On August 16, 2016, outside of the construction office, the main electrical panel on the West wall of the hotel building was not marked or labeled to indicate what each breaker controlled.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.502 I03

Other-than-serious 20 instances 25 exposed
Issued
Sep 30, 2016
Abate by
Oct 13, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.502(i)(3): All covers were not secured when installed so as to prevent accidental displacement by the wind, equipment, or employees:    a) On August 16, 2016, at the Nikko Construction site, approximately 75 pile holes were bored that were 16" in were covered with unsecured and deteriorated plywood.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Asanuma Corporation's full OSHA safety record →