NORFOLK, VA —
OSHA Inspection: LYON SHIPYARD
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of LYON SHIPYARD in 1818 BROWN AVE., NORFOLK, VA 23504 (NAICS 336611). OSHA activity number 340853753.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LYON SHIPYARD
- Site address
- 1818 BROWN AVE.
- City
- NORFOLK
- State
- VA
- ZIP
- 23504
- Mailing
- P.O. BOX 2180, NORFOLK, VA 23501
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336611
- Employees
- 225
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.101 B
- Issued
- Dec 16, 2015
- Penalty
- Initial $2,862 · Current $2,003 Reduced
General-duty citation text
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tank cars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6. Section 3.4.12, Compressed Gas Association Pamphlet P-1-1965, as adopted by 29 CFR 1910.101(b): Connections to piping, regulators and other appliances were not always kept tight to prevent leakage. a) Lyon Shipyard, Concrete Pier: On or about 08/14/2015, an oxygen regulator was connected to the pier manifold that was not tight at the joint between the flash arrestor and hose to prevent leakage. No abatement certification or documentation required.
Recent events (2)
- — I (S) $2003.4
- — Z (S) $2862
1915.55 G02
- Issued
- Dec 16, 2015
- Penalty
- Initial $5,049 · Current $3,534 Reduced
General-duty citation text
29 CFR 1915.55(g)(2): Torches were not inspected at the beginning of each shift for leaking shut-off valves, hose coupling(s) or tip connections. a) Lyon Shipyard, Vessel Terrapin Island: On or about 08/13/2015, compressed liquefied petroleum gas (Star-Flame) was supplied from an in-plant tank to a manifold, regulator, hoses, and torch. The torch was not tight to prevent leakage as a result an employee received minor burns resulting from an explosion. No abatement certification or documentation required.
Recent events (2)
- — I (S) $3534.3
- — Z (S) $5049
More inspections at Lyon Shipyard
View Lyon Shipyard's full OSHA safety record →
More inspections in this industry (NAICS 336611)
More inspections in VA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340853753.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.