Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SENECA STEEL ERECTORS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SENECA STEEL ERECTORS, INC. in 975 EAST MAIN STREET, LOGAN, OH 43138 (NAICS 238120). OSHA activity number 341239358.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Seneca Steel Erectors, INC. — free Get an email when a new federal OSHA severe-injury report for Seneca Steel Erectors, INC. is published. One employer, no account, unsubscribe in one click.
Site address
975 EAST MAIN STREET
City
LOGAN
State
OH
ZIP
43138
Mailing
975 EAST MAIN STREET, LOGAN, OH 43138
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
53
Ownership type
A

4 citations on file for this inspection.

1910.253 B02 II

Serious Gravity 5 1 instance 10 exposed
Issued
Jun 29, 2016
Abate by
Jul 12, 2016
Penalty
Initial $2,975 · Current $2,083 Reduced
29 CFR 1910.253(b)(2)(ii): Inside of buildings, cylinders shall be stored in a well-protected, well-ventilated, dry location, at least 20 (6.1 m) feet from highly combustible materials such as oil or excelsior. Cylinders should be stored in definitely assigned places away from elevators, stairs, or gangways. Assigned storage spaces shall be located where cylinders will not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons. Cylinders shall not be kept in unventilated enclosures such as lockers and cupboards.  a. On or about February 9, 2016, located in the fabrication/maintenance building, the employer did not ensure oxygen and acetylene bottles were secured to protect the cylinders from being knocked over, thereby exposing employee to a struck-by hazard.
Recent events (2)
  • — I (S) $2082.5
  • — Z (S) $2975

1910.253 B04 III

Serious Gravity 5 1 instance 10 exposed
Issued
Jun 29, 2016
Abate by
Jul 12, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage shall be separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour.  a. On or about February 9, 2016, located in the fabrication/maintenance building, the employer did not ensure oxygen bottles were separated with a 20 foot separation or a fire-resistance barrier from acetylene bottles, thereby exposing employees to a fire hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.157 C01

Other-than-serious 3 instances 10 exposed
Issued
Jun 29, 2016
Abate by
Jul 14, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): The employer shall provide portable fire extinguishers and shall mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury.   a. On or about February 9, 2016, located in the fabrication/maintenance building on the left side of the south garage door, the employer did not identify a fire extinguisher so that it would be readily accessible to employees.    b. On or about February 9, 2016, located in the fabrication/maintenance building on the right side of the south garage door, the employer did not identify a fire extinguisher so that it would be readily accessible to employees.   c. On or about February 9, 2016, located in the fabrication/maintenance building where the welding generators were stored, the employer did not identify a fire extinguisher so that it would be readily accessible to employees.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.178 A04

Other-than-serious 1 instance 10 exposed
Issued
Jun 29, 2016
Abate by
Jul 20, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation shall not be performed by the customer or user without manufacturers prior written approval. Capacity, operation, and maintenance instruction plates, tags, or decals shall be changed accordingly.  a. On or about February 9, 2016, located throughout the facility, forklifts were modified with drilled holes in the end of the tines for pulling trailers or below-the-tine hoisting which could affect the safe capacity and operation of the forklift.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Seneca Steel Erectors, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341239358.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.