Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SENECA STEEL ERECTORS INC

Special Programs inspection · Safety discipline

On , OSHA opened a special Programs safety inspection of SENECA STEEL ERECTORS INC in BLDG 917 NIAGARA FALLS AIR FORCE RESERVE WING, NIAGARA FALLS, NY 14301 (NAICS 238120). OSHA activity number 348454018.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Seneca Steel Erectors INC — free Get an email when a new federal OSHA severe-injury report for Seneca Steel Erectors INC is published. One employer, no account, unsubscribe in one click.
Site address
BLDG 917 NIAGARA FALLS AIR FORCE RESERVE WING
City
NIAGARA FALLS
State
NY
ZIP
14301
Mailing
611 INDIAN CHURCH ROAD, WEST SENECA, NY 14224
Inspection type
Special Programs (K)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
9
Ownership type
A

1 citation on file for this inspection.

1926.760 A01

Serious Gravity 5 1 instance 10 exposed
Issued
Sep 4, 2025
Penalty
Initial $1,809 · Current $1,000 Reduced
29 CFR 1926.760(a)(1): Each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems, or fall restraint systems:  a) On or about 08/20/2025 at a construction project located at BLDG 917 on Niagara Falls Air Force Reserve Wing Base in Niagara Falls NY; employees were installing a metal roof on a pre-engineered building with an eave height of 50 feet. There was no fall protection in use.  NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1809

View Seneca Steel Erectors INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348454018.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.